ETAS
Installation
XETK-S21.0B
-
User
Guide
27
5
Installation
This chapter contains information about the following topics:
• Connection to the ECU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
• Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5.1
Connection to the ECU
For connecting the XETK-S21.0 to the ECU two XETK adapter cables are rec
-
ommended:
• at CON6 adapter ETAI10
• at CON7 adapter ETAI5 or ETAI6 or ETAI8
The adapter cables are to be ordered separately (refer chapter “Ordering Infor
58).
The suitable connectors JST-7 and Samtec-10 (see Fig.
2 for additional con
-
nector details) should have been populated onto the ECU PCB for adapters
ETAI10 and ETAI5/ ETAI6/ ETAI8.
Fig.
5
-
1
XETK-S21.0 Connection to the ECU
CAUTION
Some components of the interface board may be damaged or destroyed by
electrostatic discharges. Please keep the board in its storage package until
it is installed.
The board should only be taken from its package, configured, and installed at
a work place that is protected against static discharge.
CAUTION
Risk of short circuiting the internal signals of the XETK!
When you mount the XETK to the ECU, you must ensure that the screws and
washers used will not penetrate the XETK printed circuit board.
ETAI5 or ETAI6 or ETAI8
XETK-S21.0
ETAI10