ES5100.1 Desktop Housing - User’s Guide
35
ETAS
Technical Data
Environmental Conditions
5.1
Fulfilled Standards and Norms
The ES5100.1 Desktop Housing complies with the following standards and
norms:
The housing is only designed for use in industrial environments compliant with
IEC 61326-1. Avoid any possible radio interference when using the housing out-
side industrial environments with additional shielding measures!
Environment
Only use inside closed and dry rooms
Protection rating
IP20
Max. rate of pollution
2
Maximum altitude
2000 m/6500 ft
Permissible ambient temperature
during operation
5 °C to 40 °C (41 °F to 104 °F)
Permissible storage temperature
-20 °C to +65 °C (-4 °F to 149 °F)
Relative humidity
0 to 95% (non-condensing)
Standard
Testing
IEC 61326-1
Electrical equipment for measurement, control and laboratory
use
EMC requirements (industrial environment)
IEC 61010-1
Safety requirements for electrical equipment for measurement,
control and laboratory use - Part 1: General requirements
WARNING!
This is a Class A device. This device can cause radio interference in
residential environments. In this case, the operator can be required to
take appropriate measures.