7.2
Launch
7.2.1
Disconnection Device
Disconnection device must be provided in the end product.
7.2.2
MAIN SWITCH
Switching on the MAIN SWITCH provides power to ES4700.1-B and to the ONLY SERVICE
socket-outlet.
Fig. 7-2
MAIN switch
7.2.3
CONTROL ON/OFF switch
Switches on the ES4700.1-B. All internal components are being powered. Provides power to
the PROTECTED POWER L1, -L2 and -L3 power plugs on the back side. The DC voltages on
the X8 connector are also available.
Fig. 7-3
CONTROL ON/OFF switch
7.2.4
BATTERY ON/OFF switch
Provides power to the BATTERY connector. It can be switched on/off only if the CONTROL
ON/OFF switch is activated.