ETAS
Installation
BR_XETK-S3.0
-
User Guide
32
5.1.3
Fixing the BR_XETK-S3.0 without Mounting Bracket
This chapter describes an example to mount the BR_XETK-S3.0 without the
mounting bracket. Mounting material excluding the gap pad has to be provided
by customer for the special use case.
5.1.3.1
Mounting Material
For mounting the BR_XETK-S3.0 on the ECU housing without mounting bracket
following parts are needed:
• Gap pad for the thermal mounting to the ECU housing (including BR_X
-
ETK-S3.0 delivery content or as spare part)
• 2 spacers (height = 2.30 mm, external diameter = 5.0 mm, M2 female
thread)
• 2 screws M2 x 10, countersunk head
• 2 nuts M2
5.1.3.2
Mounting the BR_XETK-S3.0
Tab.
5
-
2
List of part numbers used in BR_XETK-S3.0 mounting description
figures
To prepare the ECU Housing
1. Drill two holes through the ECU housing.
Use the measures in figures in chapter 5.1.2 on
30 and in
2. Lower the holes on the outer side of the ECU housing.
3. Insert the screws through the holes in the housing.
4. Screw the screws from the inside of the housing with the spac
-
ers.
5. Seal the housing with the holes.
To mount the BR_XETK-S3.0 on the ECU Housing
1. Place the gap pad correctly between the spacers.
2. Set the BR_XETK-S3.0 on the screws.
3. Attach the BR_XETK-S3.0 with nuts M2.
Number in
figures
Quantity
Order Name
Order Number
1
1
BR_XETK-S3.0A Emulator Probe
for the Infineon AURIX micropro
-
cessor family, delivery includes
gap pad (F 00K 110 752)
F 00K 110 751
or
BR_XETK-S3.0C ECU interface for
the Infineon AURIX TC4xx micro
-
controller family includes gap pad
(F 00K 110 752)
F 00K 113 470
2
1
Gap pad as spare part for
BR_XETK-S3.0
F 00K 110 752