Records
Cleaning (customer)
45
3.8
Cleaning (customer)
Cleaning is to be carried out once a year or after 2500 hours.
Comments:
Tasks
Notes
Empty the ash box
•
Remove excess ash from secondary combustion chamber
•
Empty the ash box
•
Check the seals
Check the pressure of the heating system
_________ bar
Check safety devices
•
Visual check of the safety valves
•
Visual check of the thermal relief valve
Chimney
•
Clean the flue tube
•
Flush the chimney's condensate drain
Clean combustion chamber
•
Clean inside of the secondary combustion chamber
•
Clean tilting grate
•
Clean secondary air openings
•
Clean ignition tubes
•
Check firebed button and firebed switch
•
Check refractory lining
Clean heat exchanger
•
Clean heat exchanger and downdraft channel
•
Clean lambda probe
•
Check heat exchanger tubes
•
Check heat exchanger cleaner
•
Clean the housing of the frequency converter
•
Inspect seals on heat exchanger covers
Clean flue gas recirculator
•
Clean flue gas recirculation piping
•
Inspecting seals on maintenance covers
performed on: _________________________