38
www.eta.co.at
Software version X.36.0 and later
ETAtouch controller
10.2.2
Setting a time window
Setting the charging and operation times
In some function blocks, the time window for charging
the tank (for example the buffer and hot water tank), or
the operating times (for example for the heating circuit)
are set. This time window must be created in the
settings of the respective function block.
Subsequently, the setting of the charging times
and temperatures will be described in relation to
the hot water tank. This example applies accordingly to
other function blocks.
Open the overview of the time window settings
1. Open the settings for the function block with the
[Settings] button.
Fig. 10-8: Open the settings
2. Access the charge times of a particular day with
the
[Charging times Daily plan] button.
Fig. 10-9: Access charging times
3. An overview screen opens.
Fig. 10-10: Overview
1
Selected time window (charging times or operating
times)
2
Select day of the week
3
Add another time window
4
Graphical representation of the time window
setting
5
Overview of all time windows for the entire week
6
Delete time window
7
Adjustable target temperature.
This is dependent on the function block, and, in this
example, corresponds to a hot water temperature
of 55 °C.
8
Period of the time window.
In this example, the hot water is charged between
08:00 a.m. and 8:00 p.m. to 55 °C.
9
Set-back temperature.
Outside the time window, the hot water is charged
to this set temperature.
Setting the time window is described below.