Leveling the unit
915 mm
1075
mm
To do this adjust the two leveling feet at front of the unit.
If the unit is not level, the doors and magnetic seal alignments will not
be covered properly.
Note: Above pictures are for reference only.
Positioning
Install this appliance at a location where the ambient temperature corresponds to the
climate class indicated on the rating plate of the appliance. For refrigerating appliances
with climate class:
- extended temperate: ‘this refrigerating appliance is intended to be used at ambient
temperatures ranging from 10 °C to 32 °C (SN)
- temperate: ‘this refrigerating appliance is intended to be used at ambient
temperatures ranging from 16 °C to 32 °C (N)
- subtropical: ‘this refrigerating appliance is intended to be used at ambient
temperatures ranging from 16 °C to 38 °C (ST)
- tropical: ‘this refrigerating appliance is intended to be used at ambient
temperatures ranging from 16 °C to 43 °C (T)
This appliance is not intended for use at altitudes exceeding 2000 m.
Location
The appliance should be installed well away from sources of heat such as radiators,
boilers, direct sunlight etc. Ensure that air can circulate freely around the back of the
cabinet. To ensure best performance, if the appliance is positioned below an overhanging
wall unit, the minimum distance between the top of the cabi-net and the wall unit must be at
least 100 mm. Ideally, however, the appliance should not be positioned below overhanging
wall units. Accurate leveling is ensured by one or more adjust-able feet at the base of the
cabinet. This refrigerating appliance is not intended to be used as a built-in appliance.
WARNING!
It must be possible to disconnect the appliance from the mains power supply; the
plug must therefore be easily accessible after installation.
Electrical connection
•
Before plugging in, ensure that the voltage and frequency shown on the rating plate
correspond to your domestic power supply. The appliance must be earthed. The power
supply cable plug is provided with a contact for this purpose. If the domestic power
supply socket is not earthed, connect the appliance to a separate earth in compliance
with current regulations, consulting a qualified electrician.
•
A specially grounded plug has been connected to the power cable of your refrigerator.
This plug should be used with a specially grounded socket of 16 amperes. If there is no
such socket in your house, please have it installed by an authorized electrician.
•
Do not use splitters, extension cords or adapters.
•
The manufacturer declines all responsibility if the above safety precautions are not
observed.This appliance complies with the E.E.C. Directives.
Summary of Contents for ETA 2539 90000E