50
www.eta.co.at
Bottom insulation
Installation
The cables may not run along the stoker duct
since this warms up during operation.
Fig. 9-40: Stoker duct
Install the sensor for the stoker screw and set a
clearance of 2 - 3 mm. Plug the stoker screw and the
dosing screw into the plug connections (marked in
colour) on the cable harness.
Fig. 9-41: Cable guide
Connect boiler to potential equalisation
The boiler must be connected to the potential equaliza-
tion of the boiler room or the building. Country-specific
regulations must be observed.
The runners of the boiler features holes to
connect the potential equalisation (minimum
cross-section 6 mm²).
Fig. 9-42: Connect potential equalisation
9.9
Bottom insulation
Pushing in floor insulation
Connect both troughs with M5 x 6 screws. The screws
are located in the ash box. Then lay the insulation in
the floor pan.
Fig. 9-43: Floor pan