Technical Specifications 

 

ET System electronic GmbH 

D

ISPLAY

 

Display 

Touch screen 

Voltage 

Display: 0 - 300 V, Resolution: 0.1 V, Accuracy: 0.5 % FS + 4COUNT 

Current 

Display: 0 - 999,9 A, Resolution: 0.1 A, Accuracy: 0.5 % FS + 4COUNT 

Frequency 

Display: 0 - 999,9 Hz, Resolution: 0.1 Hz, Accuracy: ± 0.1 Hz 

I

NPUT 

S

PECIFICATIONS

 

Number of Phases 

Voltage 

230/400 V 

Voltage Fluctuation 

230/400 V ± 15 % 

Frequency Fluctuation 

50/60 Hz ± 3 Hz 

Power Factor 

0.9 

Max. permitted current under full load 

140.3 A 

O

UTPUT 

S

PECIFICATIONS

 

Number of Phases 

Wave Form 

Sine 

Low Voltage 

0 - 150 V (L - N) 

High Voltage 

150.1 - 300 V (L - N) 

Frequency 

45 - 500 Hz 

Frequency Stability 

±≤ 0.

01 % 

Max. high voltage current 

LO: 83.3 A 

Max. low voltage current 

HI: 41.7 A 

T

OTAL 

P

OWER

 

Output Power (kVA) 

75 

Circuit Mode 

IGBT/PWM (pulse width modulation) 

Voltage Control 

≤ 1 %

 

Load Control 

± 1 % 

Wave Form Distortion (THD) 

≤ 2 %

 

Efficiency 

≥ 90 %

 

Reaction Time 

≤ 2 ms

 

Crest Factor 

3:1 

Protective Devices 

Input: fuse switch, Output: overvoltage/undervoltage, overcurrent, overload                        Input: 
overvoltage/undervoltage,  countercurrent  protection,  overtemperature,  short  circuit  protec-
tion, conduct fast protection and lock fault protection , error display 

Summary of Contents for EAC/AFV

Page 1: ...ET System electronic GmbH Telefon 06205 3948 0 Fax 06205 37560 Hauptstra e 119 121 info et system de 68804 Altlu heim www et system de EAC AFV...

Page 2: ...Software version January 2015...

Page 3: ...Block Diagram 5 Structure of the Main Control Unit 6 Description of cable connections 6 Cable Wiring 6 General Settings 7 Initial State Splash Screen 7 Main Menu 7 Application 7 System 7 Event 7 Menu...

Page 4: ......

Page 5: ...c are flexibly carried out by qualified personnel The approval procedures are performed within the scope of development planning and thus do not negatively impact the start of manufacturing Permanent...

Page 6: ...OUTPUT SPECIFICATIONS Number of Phases 3 Wave Form Sine Low Voltage 0 150 V L N High Voltage 150 1 300 V L N Frequency 45 500 Hz Frequency Stability 0 01 Max high voltage current LO 83 3 A Max low vo...

Page 7: ...ystem electronic GmbH 3 TECHNICAL DRAWING 1 Touchscreen 2 AC Output terminal row U V W Nu Nv Nw 3 Emergency stop button 4 Door handle 5 Input air switch 6 Maintenance socket 7 AC input terminal row R...

Page 8: ...ted in case it needs to be transported in the future or claims for compensation need to be asserted SETTING UP To avoid electric shocks and product failure the device should be installed in a temperat...

Page 9: ...to the output terminal disk through the contactor 9 Lightning Protection Device overvoltage protection lightning protection restraining surge current absorbing spike pulse etc 10 Voltage Sampling inp...

Page 10: ...be selected according to the cables recommended in the following tables Input distribution cables Input Current A Input live wire mm Input zero line mm Input ground wire mm A B C 70 8 A 25 mm 25 mm 2...

Page 11: ...and the input switch connected Before the user should ensure that no electrical current is flowing at the input terminal row When switching on the unit the splash screen and the initialization graphi...

Page 12: ...ing the values are the arrow buttons besides the slide control By clicking these buttons the value changes by 0 1 interval Volt Range After clicking the button LOW the unit is on low voltage After cli...

Page 13: ...H 9 Mode Step Download Parameter Starts the download of the adjusted parameters Operation Mode Step is activated after button RUN was clicked and deactivated after button STOP was clicked RESET sets t...

Page 14: ...electronic GmbH The button in the upper right field of the display switches between adjustment function and graphical display of the mode Step Mode Gradual Download Parameter Starts the download of t...

Page 15: ...cked RESET sets the unit back to its initial state The button in the upper right field of the display switches between adjustment function and graphical display of the mode Gradual Mode Meas Operation...

Page 16: ...Main Menu 12 ET System electronic GmbH Error Message Operation A click on the button RESET resets the error meassage Clicking OK switches to the previous display MENU SYSTEM...

Page 17: ...ead but cannot be changed by the user In case that adjustments shall be made please contact our service Language Setting Adjusts the menu language The button Back saves these settings and switches to...

Page 18: ...CTIONS Control 0x00 0x0F Adjustment 0x10 0x1F Adjustment Data Functions 0x20 0x2F Data Enquiry 0x30 0x31 Application parameter 0x16 0x17 Command for standard address 0x02 ANSWER COMMANDS 0 x 02 Addres...

Page 19: ...from unit 0x02 0x50 0x01 0x00 0x00 0x1D Reset 0x03 Send command 0x02 address 0x03 function code 0x00 command length 0xD0 CRC Checksum high byte 0xF0 CRC Checksum low byte Answer from unit 0x02 0x50 0x...

Page 20: ...ge of this group 110 V x 10 0x01 0xF4 output frequency of this group 50 Hz x 10 0x08 0x98 output voltage of this group 220 V x 10 0x02 0x58 output frequency of this group 60 Hz x 10 0x00 0x00 0x00 0x0...

Page 21: ...100 kVA x 10 0x03 0xE8 V phase Apparent power 100 kVA x 10 0x03 0xE8 W phase Apparent power 100 kVA x 10 0x00 0x63 U phase Power Factor 0 99 x 100 0x00 0x63 V phase Power Factor 0 99 x 100 0x00 0x63 W...

Page 22: ...0 0x41 0x00 0xC1 0x81 0x40 static unsigned char auchCRCLo 256 0x00 0xC0 0xC1 0x01 0xC3 0x03 0x02 0xC2 0xC6 0x06 0x07 0xC7 0x05 0xC5 0xC4 0x04 0xCC 0x0C 0x0D 0xCD 0x0F 0xCF 0xCE 0x0E 0x0A 0xCA 0xCB 0x0...

Page 23: ...4 IGBT Phase W is damaged Check and replace IGBT Err 13 Radiator over temperature Fan malfunction Check fan Err 14 Transformer over temperature Fan malfunction Check fan Err 15 Emergency stop button E...

Page 24: ...Notes 20 ET System electronic GmbH NOTES...

Page 25: ...Notes ET System electronic GmbH 21...

Reviews: