INSTALLATION
For achieving the best results the capacitor should be located close-by the
amplifier. The cables between capacitor and amplifier should be short as pos-
sible and should have large cross section. While installing the cables or the
operation, ensure not to damage the insulation of the cables.
Tightly screw the device with the supplied brackets and screws as close as
possible to the amplifier on a mechanically stable position. By no means install
the capacitor on any kind of speaker enclosure or on high vibrating positions.
The correct wiring is displayed on the next page. To avoid any interferences,
connect the capacitor’s ground connection at the same ground terminal like
the amplifier.
INITIAL CHARGING
For the first initial charging use by any means the supplied light bulb, to limit
the charge current and to avoid connecting sparks. Connect the ”–” ground wire
with the ”–” terminal of the capacitor.
Then clamp the supplied light bulb to the ”+” terminal of the capacitor and hold
the ”+” wire of the battery or distribution block at the other end of the light bulb.
The light bulb stops lighting when a voltage of 10 volts has been reached and
can then be removed. Then connect the “+” terminal of the battery with the “+”
terminal of the capacitor to complete the charging process until 12~14 volts
are achieved.
The light bulb may get very hot during the charging process. Please avoid any
short circuit on the terminals.
Ground Terminal
Battery Terminal
Light Bulb
+