26
user manual LokSound / LokSoundXL V3, 1st edition, 07/2004
List of all supported CVs
1
Engine address
Address of engine
1-127
3
2
Start voltage
Sets the minimum speed of the engine
1-75
3
3
Acceleration
This value multiplied by 0.869 is the time from stop to
0-64
8
maximum speed
4
Deceleration
This value multiplied by 0.869 is the time from maximum 0-64
6
speed to stop
5
Maximum speed
Maximum speed of engine
0-64
64
6
Medium speed
Medium speed of engine
0-64
22
7
Version number
Internal software version of LokSound decoder
8
Manufacturer’s ID
Manufacturer’s ID - ESU –
151
Writing value 8 in this CV triggers a reset to factory values
13 Analogue mode F1-F8 Status of functions F1 to F8 in analogue mode
0-255
0
Bit Description
value
0 function F1
1
1 function F2
2
2 function F3
4
3 function F4
8
4 function F5
16
5 function F6
32
6 function F7
64
0 function F8
128
14 Analogue mode FL,
Status of functions FL, F9 to F12 in analogue mode
0-255
3
F9-F12
Bit Description
value
0 function FL (f)
1
1 function FL (r)
2
2 function F9 (f)
4
3 function F10 (f)
8
4 function F11
16
5 function F12
32
6 function F9 (r)
64
0 function F10 (r)
128
17 Extended engine address long address of engine
18
CV17 contains byte with higher value
(bit 6 and 9999, bit 6 and bit 7 must always be active),
CV18 contains byte with lower value. Only
active when function is switched on in CV 29(see below).
CV name
description
range
default