6 Main menu
6.1.5 Service
WARNING !!!
Access the service is intended only for qualified technical personnel. The
changes may cause malfunction of the system.
Service
Function
Description
Comf. MAX pump temp.
Maximum outdoor temperature at which the
circulating pump can work in a comfortable
range.
Econ. MAX pump temp.
Maximum outdoor temperature at which the
circulating pump can work in a economic
range.
MIN Tch pump
Minimum temperature calculated for central
heating at which the circulating pump can be
operated.
Source
Specifies the source of energy for central
heating circuit.
Temperature MAX
Maximum temperature for central heating.
Mixer time
Time of full opening of the mixer.
Hot water priority
Priority for hot water of the heating circuit.
During heating hot water the central heating
pump is not working.
Pump test
Starts the pump regardless of other
conditions.
Mixer test
Starts the mixer motor independently of the
other conditions.
Circ. name
Gives name for the central heating circuit.
CH temp. for -20°C
The point of the heating curve for -20 ° C.
CH temp. for 0°C
The point of the heating curve for 0 ° C.
CH temp. for 10°C
The point of the heating curve at 10 ° C.
page 26