E200P Operation Manual
22
Parameter
Default
Range
Unit
Description
DLY
0~99.99
s
In case of single step, delay
time for X-axle retracting.
PP
0~9999
-
The number of processing
workpiece in this program.
CP
0~9999
-
PP=0: this value is the
current work piece.
PP>0: this value is the
remain work piece.
OPN
0~999.999
mm/inch
After bending, the distance
of the Y-axis opening.
PROGRAM
ST
0~25
-
The total number of steps in
this program.
PP
0~99999
-
The number of processing
workpiece in this program.
CP
0~99999
-
PP=0: this value is the
current work piece.
PP>0: this value is the
remain work piece.
DLY
0~99.99
s
In case of single step, delay
time for X-axle retracting.
HT
0~99.99
s
The interval time from
LDP
signal to decompression
process.
STEP
XP
0~9999.999
mm/inch
Program position of X axis.
YP
0~9999.999
mm/inch
Program position of Y-axis.
DX
0~9999.999
mm/inch
Retract distance of X axle.
OPEN DIST
0~999.999
mm/inch
After bending, the distance
of the Y-axis opening.
Repeat Times
1~99
-
The repeat times in this
step.
Summary of Contents for E200P