9
REPAIR
If the product is not working properly, check the following points:
Problems / Symptoms
Causes
Solutions
No mist when the
appliance is switched on
The appliance is not plugged in
Ensure that the USB lead is correctly connected to the device
and the USB port
Water level too low
Fill the water container
Water level exceeds 100 ml
Empty out excess water
The end of part A is obstructed
Make sure that nothing is preventing the release of the mist
Mist stops while
the diffuser
is in operation
Water level too low
Fill the water container
Accumulation of water drops in the part A
Switch off the diffuser, remove part A then clean off the
accumulated water drops
Insufficient mist
The ceramic disk is dirty
Clean the ceramic disk as described in the « PRECAUTION
FOR USE » instructions
An excess of Estéban refresher oils or essential
oils has been poured into the container
Empty the appliance and clean it
Accumulation of water drops in the part A
Switch off the diffuser, remove part A then clean off the
accumulated water drops
The light does not
switch on
Diffuser failure
Bring the diffuser back to the retailer within the after-sales
service support legal deadline
Should the problems persist please contact your retailer.
The manufacturer is not responsible for damages caused by improper use of the diffuser.
Power supply
USB 3 / 5V - 1A
Mains
Compatible with USB mains adapter – Output: 5V 1A
Power
5 W
Summary of Contents for CMP-167
Page 26: ...26 steban Est ban www esteban fr A 1 B h 2 LIGHT 3 ON OFF 4 5 6 7 C USB A B C...
Page 28: ...28 8 Est ban...
Page 29: ...29 USB USB 100 A A A A A UBS 3 5B 1A USB 5 1A 5...
Page 31: ...31...
Page 36: ...36...