8
6. Internal (inside machine) or
6. See dealer
external solution line damaged
and leaking
TROUBLE SHOOTING (CONTINUED)
PROBLEM
CAUSE
SOLUTION
5. 1000 PSI Plunger
1. Pressure regulator valve
1. Adjust pressure using
pump runs but has
out of adjustment
regulator located at the
loss of pressure
front of the machine
2. Partial kink in solution hose
2. Remove kink
3. Partial blockage in solution
3. Remove blockage
hose
4. Jet orifice opening on clean- 4. Total jet opening for
ing wand is too large 1000 PSI pump
should be .04
5. Pressure regulator valve
5. See dealer
components wearing out
6. Internal pump components
6. See dealer
wearing out
6. Vacuum operates
1. Recovery tank full
1. Drain recovery tank
but has poor or no
suction
2 Vacuum hose plugged
2. Locate and remove
blockage
3. Wand plugged
3. Locate and remove
blockage
4. Exhaust port blocked
4. Locate and remove
blockage
5. High level float stuck in off
5. Turn vacuum off and tap
position
top of float screen cage
Summary of Contents for e1200
Page 12: ...11 E1200...
Page 13: ...12 E1200 PARTS LIST...
Page 17: ...16 1000 PSI PUMP KITS...
Page 18: ...17 E1200 WIRING...
Page 19: ...18...
Page 24: ...23 E1200 Pump out cleaning procedure...
Page 26: ...25 YOU MAY NEED TO LOOSEN UNION WITH CHANEL LOCK PLYERS BY TURNING COUNTER CLOCK WISE...
Page 27: ...26 SPIN UNION NUT COUNTER CLOCK WISE TO SEPARATE FROM BALANCE OF FITTINGS...
Page 28: ...27 GIVE PLUMBING ASSEMBLY A SLIGHT TUG TO DISENGAGE FROM PUMP...
Page 29: ...28 PLUMBING ASSEMBLY REMOVED...
Page 30: ...29 PRESS IN RED CLIPS AND LIFT PUMP OFF RED STRAINER...
Page 31: ...30 PUMP REMOVED FROM STRAINER CAGE...
Page 32: ...31 S S SCREEN LIFTS OUT OF STRAINER CAGE TO BE CLEANED...