Esteam e1200 Owner'S Manual Download Page 27

 

26 

SPIN UNION NUT COUNTER CLOCK – WISE TO SEPARATE 

FROM BALANCE OF FITTINGS

 

 

Summary of Contents for e1200

Page 1: ...new E1200 hard surface and soil extractor built in Canada by Esteam Cleaning Systems Our goal has been to produce the best high performance line of cleaning equipment on the market today Reading your...

Page 2: ...NTS Page No Introduction on the E1200 2 Specifications 2 Maintenance 3 Safety Information 3 Operating Instructions 4 Trouble Shooting 7 Schematic 10 Warranty Registration 18 Warranty 19 Pump out Clean...

Page 3: ...hard surface and carpet cleaning with it s adjustable 1000 PSI solution pumps The E1200 s clean water solution tank and the dirty water recovery tank both have a 40 litre capacity Built into the recov...

Page 4: ...inse out pump with clean water at conclusion of work day Clean poly housing with mild soap and water Check machine fuse MONTHLY Clean air inlet and check exhaust port Check to make sure cooling fan is...

Page 5: ...ver bend or remove ground pin from plugs 5 Ensure filters and screens are free from lint or dirt 6 Do not run unit if vacuum motor or pump are wet Allow sufficient time for motor to dry before pluggin...

Page 6: ...stable from 400 1000 PSI To adjust pressure turn the regulator located on lower front of machine clockwise to increase pressure and counter clockwise to decrease pressure 7 Attach the prime hose to th...

Page 7: ...solution tank Continue until all water has been removed from solution tank and transferred into recovery tank Drain recovery tank WARNING When using electrical equipment around water it is important t...

Page 8: ...PSI Plunger 1 Switch not turned on 1 Turn on switch pump will not run 2 Broken switch 2 See dealer 3 Blown fuse 3 Replace fuse 4 Loose wiring 4 See dealer 5 Pump motor defective 5 See dealer 6 Motor...

Page 9: ...lution 3 Remove blockage hose 4 Jet orifice opening on clean 4 Total jet opening for ing wand is too large 1000 PSI pump should be 04 5 Pressure regulator valve 5 See dealer components wearing out 6 I...

Page 10: ...oat screen cage TROUBLE SHOOTING CONTINUED PROBLEM CAUSE SOLUTION 8 Machine spits water 1 High level float not working 1 Check auto shut off float out of exhaust port properly cage and ball for proper...

Page 11: ...10 2 Pump leaking 2 Immediately shut unit down Bring unit to a dealer for service 3 Solution or recovery tank 3 Immediately shut unit leaking from above down Bring to a dealer for service...

Page 12: ...11 E1200...

Page 13: ...12 E1200 PARTS LIST...

Page 14: ...t 1 4 x 20 Nylon Zinc 20 400 165 Locknut 1 2 21 405 010 Bolt 1 4 x 1 SS 22 405 020 Bolt 1 4 x 1 1 4 SS 23 405 065 Bolt 1 4 x 6 Stove Zinc 24 405 210 Bolt 5 16 x 1 GR5 Zinc 25 405 615 CS 1 4 x 1 2 SS H...

Page 15: ...1 4 FPT Extruded 72 555 208 Elbow 90 1 4 Street Extruded 73 555 212 Elbow 90 1 4 Street Extruded 74 555 272 Hex Nipple 1 4 75 555 328 Hose barb 90 1 2 Barb x 3 8 MPT 76 555 370 Hose Barb 1 2 Barb x 1...

Page 16: ...MPT 106 590 415 PVC ADPT 1 1 2 S x MPT 107 595 005 ABS Pipe 1 1 2 108 597 010 Fload Screen Cage Sealed 109 597 061 Adpt RM 30 Degree 110 597 065 Valve Diaphragm Auto Fill 111 800 035 Alum 100 112 845...

Page 17: ...16 1000 PSI PUMP KITS...

Page 18: ...17 E1200 WIRING...

Page 19: ...18...

Page 20: ...al customer other than as maybe provided for in this warranty In the event a defect occurs in a E1200 Housing Unit subsequent to five years and thereafter for life of receipt by the original customer...

Page 21: ...the control of Esteam and iii No warranty is provided for mechanical or electrical breakdown or failure of an Esteam product resulting from ordinary wear and tear or the consequences thereof including...

Page 22: ...GUIDELINES Defective items must be replaced through a local Esteam Distributor Replacement parts will be sent via prepaid regular ground service to the distributor The defective part must be returned...

Page 23: ...amer solution must be used bycustomer to limit foaming in the recovery tank b Vacuum Motors Require use of a defoamer A vacuum motor showing moisture contamination on interior components shall void an...

Page 24: ...23 E1200 Pump out cleaning procedure...

Page 25: ...24 UNDO THIS UNION BY TURNING COUNTER CLOCK WISE THIS 90 DEGREE FITTING SIMPLY POPS OFF THE PUMP WITH A SLIGHT TUG...

Page 26: ...25 YOU MAY NEED TO LOOSEN UNION WITH CHANEL LOCK PLYERS BY TURNING COUNTER CLOCK WISE...

Page 27: ...26 SPIN UNION NUT COUNTER CLOCK WISE TO SEPARATE FROM BALANCE OF FITTINGS...

Page 28: ...27 GIVE PLUMBING ASSEMBLY A SLIGHT TUG TO DISENGAGE FROM PUMP...

Page 29: ...28 PLUMBING ASSEMBLY REMOVED...

Page 30: ...29 PRESS IN RED CLIPS AND LIFT PUMP OFF RED STRAINER...

Page 31: ...30 PUMP REMOVED FROM STRAINER CAGE...

Page 32: ...31 S S SCREEN LIFTS OUT OF STRAINER CAGE TO BE CLEANED...

Reviews: