background image

P a r t y   M o d e   B u t t o n  

S e c u r e   l o c a t i o n  

The two wires of the party mode button should go to the Exit Loop / Exit Wand  
terminal and common. 
 
(

This method of usage is not compatible with all gate openers. It relies on the gate openers ability to 

infinitely reset the pause time through the exit loop terminal - some gate openers have a limit to the 
amount of time it will hold the pause time for auto reclose and those openers will not be compatible 
with this method. 

 
For the Estate Swing line the E-S 1100, E-S 1102, and E-SC 1102 are not compatible with this 
method. 
 
Please use this method only when the button is secure from intruders and only accessible to adults 
with a clear view of the gate from the button location. 

____________________________________________________________________ 
 
During normal operation the button should not be depressed keeping the circuit open.  

When you want the gate to stay open in party mode

1.  press the button to connect the circuit. (button will be depressed) 
2.  The gate will go open and stay open as long as the button is depressed.  
3. When you wish to have the gate close, press the button back in to release it to non-
depressed and the gate will count down its auto-reclose time and go closed.  
____________________________________________________________________ 
 
 
The button wires can be extended up to 1000 feet with 18 gauge stranded low voltage 
wire.  
 
Mount button in a secure location. If mounting in an outdoor location mount on the 
bottom of any box that may contain electronic or need to stay water tight to prevent 
water leakage.  

Reviews: