Connecting Earth

Your Mains Multiplier must be connected to an earthed wall socket, however if you do not 

have earth the Mains Multiplier will still function. Even without an earthed wall socket the 

Mains Multiplier itself will make a connection between all earth contacts of your 

equipment. This will prevent that small currents will run through your interlinks due to 

differences between earth potentials at your equipment’s chassis. So even without an 

earthed wall socket you should keep using your earthed power cords. 

On both the Mains Multiplier 6+ and Mains Multiplier 8+ you will find a tool which is unique 

for Essential Audio Tools. It is called the 

Ground Bridge

.

It consists of three terminals (one green, two black) which can be connected in two ways 

by a bridge. With the Ground Bridge you are able to choose between the earth terminal in 

your wall socket or an external earth you supply yourself. This external earth can be an 

earth pole which you can have installed by a specialized company. The earth pole 

(outside your house, deep in the ground) should have an exclusive connection to the 

position where the Mains Multiplier 6+ or Mains Multiplier 8+ is. Nothing else should be 

connected to this special earth pole. The Mains Multiplier’s green socket must be used to 

connect your external earth.

Do not plug or unplug the Ground Bridge when the Mains Multiplier is powered!

Figure 6. External earth applied

In figure 5  

you can see how the Ground Bridge is connecting the earth pin of the

 

 

wall socket with the earth connection inside the Mains Multiplier 6+ or  

 

 

Mains Multiplier 8+.        

In figure 6  

you can see how the Ground Bridge is placed so the green socket can 

 

 

be used for the external earth.

Please check the indicators, you should have two green lights. One green light means your 

earth connection is not proper.

Tips

For maximum noise reduction, it is best to keep all power and audio cables in your setup 

separated by some distance from each other and to avoid routing cables in parallel.

Use high-quality power cords (our Current Conductor for example) to connect your 

equipment. The screening will prevent stray-fields to reach your audio cables. Order your 

power cords as short as possible, for best results.

Do not connect distribution blocks or mains splitters to the outputs. It will possibly cause 

interference.

Feed ALL your equipment from the Mains Multiplier. Having an extra external power feed 

to one of your pieces of equipment will possibly cause interference and/or hum.

Figure 5. Wall socket earth applied

9.

Summary of Contents for Mains Multiplier 6+

Page 1: ...User Manual Rev 2 0 September 2015 Mains Multiplier 6 Mains Multiplier 8 essentia audiotoo s Mains Multiplier 6 Mains Multiplier 8 ...

Page 2: ...Introduction page 3 Description page 4 Safety precautions page 5 Connections page 6 Specifications page 10 Problem solving page 11 Warranty page 11 Contents ...

Page 3: ...h each other by use of the mains power supply But there is more the past 25 years switching power supplies have made their way into computers TV s and other home appliances These devices pollute the mains supply with nasty pulses This Trojan Horse comes into your equipment without knowing it The pollution has to be taken out of the mains power supply before it reaches your analogue audio equipment...

Page 4: ...nit please check our website Where to use Wherever you need to connect multiple loads to the mains the Mains Multiplier is the best choice Of course you will have to use high performance power cords else the Mains Multiplier will not perform at its best It s a combination of factors only if you use the Mains Multiplier in combination with high performance power cords like our Current Conductor you...

Page 5: ...s product into a grounded outlet through a ground conductor including mains cord may result in personal injury or damage to your equipment Call a licensed electrician if you are unsure if your AC outlets are properly grounded Do not overload individual outputs Do not connect loads which draw more current than the maximum rating for each individual outlet Possible damages due to exceeding these max...

Page 6: ...ion by a red light you should reverse the power cable plug in the wall socket You will see that both indicators will light green which means that power is on and phase is ok For countries with an earth pin in the middle of the wall socket France Belgium it is not possible to reverse the power cord plug in the wall socket You should ask a technician to reverse the neutral and phase in your wall soc...

Page 7: ...de filter This group is meant to feed pre amplifiers digital surround processors light to medium subwoofers Integrated amplifiers can go on this group as well but please check power carefully The maximum currents or power you can draw from each group is different Group I 4 outputs maximum 10A each maximum 16A in total Group II 2 outputs maximum 6A each maximum 16A in total To prevent that you do e...

Page 8: ...u do exceed maximum load use the power indication W or Watt at the back of your equipment to calculate the total power for each group The value of the fuse in your equipment is not important for the calculation After checking the power use the following numbers Group I 4 outputs maximum 2300W each maximum 3680W in total Group II 4 outputs maximum 1380W each maximum 3680W in total Total maximum pow...

Page 9: ...iplier 8 is Nothing else should be connected to this special earth pole The Mains Multiplier s green socket must be used to connect your external earth Do not plug or unplug the Ground Bridge when the Mains Multiplier is powered Figure 6 External earth applied In figure 5 you can see how the Ground Bridge is connecting the earth pin of the wall socket with the earth connection inside the Mains Mul...

Page 10: ...Maximum continuous current per unfiltered socket 10 Amps Maximum continuous total current all sockets together 16 Amps Maximum continuous total power all sockets together 3680W Size 424 l x 70 w x 71 5 h in mm Weight 1 4 kg Mains Multiplier 8 Maximum continuous current per filtered socket 6 Amps Maximum continuous current per unfiltered socket 10 Amps Maximum continuous total current all sockets t...

Page 11: ...for service Problem solving Essential Audio Tools products have a warranty period of two years from date of purchase This warranty covers manufacturing defects and failures within product s specifications When warranty is claimed the original bill with the buyer s name and date of purchase should be presented Warranty will void if The device has not been used in conformance with the user manual Th...

Page 12: ...Essential Audio Tools CopyRight by Square Audio The Netherlands info essentialaudiotools com essentia audiotoo MORE INFORMATION WWW ESSENTIALAUDIOTOOLS COM s ...

Reviews: