![Esse Engineering BakeHeart Manual Download Page 105](http://html1.mh-extra.com/html/esse-engineering/bakeheart/bakeheart_manual_2428243105.webp)
OMNI-Test Laboratories, Inc.
V
m(std)
– Volume of Gas Sampled Corrected to Dry Standard Conditions, dscf
ASTM E2515 equation (6)
Where:
K
1
=
17.64
°
R/in. Hg
V
m
=
Volume of gas sample measured at the dry gas meter, dcf
Y
=
Dry gas meter calibration factor, dimensionless
P
bar
=
Barometric pressure at the testing site, in. Hg
∆
H
=
Average pressure differential across the orifice meter, in. H
2
O
T
m
=
Absolute average dry gas meter temperature,
°
R
Sample Calculation:
Using equation for Train 1:
2.30
V
m(std)
= 17.64
x 63.266 x
0.995
x
13.6
(
73.4
+
460
)
V
m(std)
=
61.732
dscf
Using equation for Train 2:
1.78
V
m(std)
= 17.64
x 66.079 x
0.991
x
13.6
(
70.4
+
460
)
V
m(std)
=
64.503
dscf
Using equation for ambient train:
0.00
V
m(std)
= 17.64
x
0.00
x
0
x
13.6
(
68.4 +
460
)
V
m(std)
=
0
dscf
+
)
( 29.49
)
+
29.49 +
)
(
( 29.49
Control No. P-SSAR-0003
Low Burn Run 2
105 of 161
Summary of Contents for BakeHeart
Page 34: ...34 of 161...
Page 35: ...35 of 161...
Page 42: ...42 of 161...
Page 43: ...43 of 161...
Page 52: ...52 of 161...
Page 53: ...53 of 161...
Page 60: ...60 of 161...
Page 61: ...61 of 161...
Page 70: ...70 of 161...
Page 71: ...71 of 161...
Page 75: ...75 of 161...
Page 76: ...76 of 161...
Page 77: ...77 of 161...
Page 78: ...78 of 161...
Page 79: ...79 of 161...
Page 80: ...80 of 161...
Page 81: ...81 of 161...
Page 82: ...82 of 161...
Page 83: ...83 of 161...
Page 85: ...85 of 161...
Page 86: ...86 of 161...
Page 87: ...87 of 161...
Page 94: ...94 of 161...
Page 96: ...96 of 161...
Page 97: ...97 of 161...
Page 113: ......
Page 159: ......