29 of 52
|
Earth Save Products-ASHP
PASRW030B-D-PS
V 1.8
PASRW040B-D-PS
PASRW050B-D-PS
there is scorching visible on the unit, make sure that the unit surroundings are
free from debris and growth of foliage from plants) and should be carried out
every 3 months and after the unit has been out of service for any prolonged
periods.
The inline filter/strainer should be cleaned regularly for the first six months
and at least once a year there after.
It is recommended that you use a high
performance filter/strainer such as the Spirotech Magna-booster 2
®
rather
than a basic “Y” strainer/filter. Please discuss this with your installer.
WARNING!
The grills on the unit are intended to protect installation engineers from injury
from the evaporator during handling and installation work.
However, the grills located over the evaporator can create a risk of clogging
with a frost or ice during very cold weather. You may remove the grills over
the evaporator during periods of very cold weather but, if you do this, you
must make sure that the evaporator is not damaged while the grills are
removed and it is therefore advisable to keep people and pets away from the
unit. Please also note that the metal "fins" on the evaporator are sharp and
you should not touch them and also prevent others touching them - they can
cause serious cuts. The fins are also fragile and you should avoid bending
them.
If in any doubt about what to do, please call your installation engineer or ESP.
WARNING!
Very important:
The 3 phase model has built-in set phase protection. If the phase
sequence is wrong or there is a phase is missing, the controller will