- 6 -
Cabinet Back
Bolts with Nuts
Front Panel
Grid
Front Edges
Fig. 4
NOTE:
It is normal for a new appliance to give off some odor the first time it is lit.
This is due to the curing of the paint and any undetected oil from the manufacturing
process.
It is recommended to secure a good room ventilation for at least two (2) hours the
first time the heater is used.
Installing the Thermostat Sensor (Fig. 5) - TE Models
(with Thermostat)
Once the heater is installed proceed to install the thermostat sensor bracket.
Extract the bulb from the bracket.
The bracket must be fixed horizontally to the wall, with the screws provided. It must
be placed at 1 cm. over the bottom of the heater, and approximately 2 cm. from the
right side of the heater.
When the bracket is fixed to the wall, place the sensor again in the bracket.
Fig. 5