MaXiO System
Manual
38
Digital Audio
Input Port Select
: This is where you can switch between the coaxial S/PDIF digital input and
the XLR AES/EBU digital input for each of the 4 digital inputs available in
each format.
PLL status
: Shows if an S/PDIF (or AES/EBU) connection is made. If
Lock
is displayed, an
S/PDIF (or AES/EBU) signal is detected at the specific input. If
Unlock
is
displayed, no signal is detected.
Format
: - Professional (IEC 958 Type 1): EX8000 digital in/out format is AES/EBU.
- Consumer (IEC 958 Type II): EX8000 digital in/out format is S/PDIF.
Note that you can set this to
Professional
but keep the RCA (S/PDIF) port. This would
allow you to process an AES/EBU signal coming in on an unbalanced S/PDIF cable.
Analog Output Level Control
: This is where you can control the analog output level for each
playback / output channel.
Summary of Contents for MaXiO 032