Concrete Finisher Manual (Version 1)
9
Pre-Start Checks
The following pre-start inspection must be performed before the start of each work session. Please
refer to the service & maintenance section for detailed guidance. If any fault is discovered, the
concrete finisher must not be used until the fault is rectified.
1.
Thoroughly inspect the machine for signs of damage. Make sure all guards are in place and
secured.
2.
Check hoses, filler openings, drain plugs and any other areas for signs of leakage. Fix any
leaks before operating.
3.
Check the engine oil level and top up as necessary. Use proper engine oil with the proper
viscosity (SAE 10W-30 recommended).
4.
Check the engine fuel level and top up as necessary. Use clean fuel. Use of contaminated
fuel would damage the fuel system. Do not overfill fuel tank, this may cause fuel spillage.
5.
Check that air filter is clean. Excessive dirt/dust accumulation within the filter element will
cause erratic engine operation. Clean the air filter element when it is contaminated. (See
Service & Maintenance Section)
6.
Check for fuel and oil leaks.
Start and Stop Procedure
Before starting the engine, make sure that the centri-safety switch is in the ON position and
the Throttle Lever is set to the IDLE position.
Figure 1 – Throttle Lever
Improper operation can be hazardous. Read and understand this section
before you start the machine.
CAUTION
FULL OPEN
IDLE