background image

Programming the Unit

Fig. 1

4

To change the Programme times

1. Press the SET button (1) four times until the programme icon (2) 

flashes, and the first ON time appears.
2. Press the +/- buttons (3) to adjust the ON time.  Please note, the 

time will change quicker if pressed continually.
3. Press the NEXT button (4).  The display will now show 1 OFF (5).
4. Press the +/- buttons (3) to adjust the OFF time.  Please note, the 

time will change quicker if pressed continually.
5.  Press  the  NEXT  button  (4)  to  access  the  remaining  ON/OFF 

periods and adjust in the same manner as above.
6. To return to RUN mode, press the SET button (1) until the display 

indicates RUN on the display.

N.B: Programming is in 10 minute segments.

(1)

(3)

(5)

(2)

(4)

Summary of Contents for ES1247

Page 1: ...ES1247 1 Channel Programmer User and Installation Instructions...

Page 2: ......

Page 3: ...it The Factory set Programme 3 Changing the Programme 4 Operating the Unit Choosing the Operating Mode 5 Using the Advance Function 6 Using the HR Boost Function 7 Basic Settings Setting the Time Date...

Page 4: ...tallation Safety Instructions Maintenance Safety Notice 11 Pre Installation Unit Set Up 12 Fitting the Back Plate 12 New Installations 13 Existing Installations 13 Wiring Diagram 14 Fitting the Progra...

Page 5: ...User Instructions...

Page 6: ...me for example Override Advance or Boost These are explained in the manufacturer s instructions The heating will not work if the room thermostat has switched the heating o And if you have a Hot Water...

Page 7: ...ds per day via a 4 position DIP switch on the back of the unit see installation instructions The large easy to read display makes programming easy and the unit is designed to eliminate the possibility...

Page 8: ...rogrammer Option the initial programme displayed will be for Monday You can go to any day of the week by pressing the DAY button repeatedly The COPY button will copy the current programme onto the nex...

Page 9: ...continually 3 Press the NEXT button 4 The display will now show 1 OFF 5 4 Press the buttons 3 to adjust the OFF time Please note the time will change quicker if pressed continually 5 Press the NEXT b...

Page 10: ...ater is ON continuously AUTO Central Heating and Hot Water will be switched ON and OFF in accordance with set programmes ALL DAY Central Heating and Hot Water will switch ON at the rst ON and switch O...

Page 11: ...e when the programme is in AUTO or ALL DAY operating modes 6 To Advance Central Heating and or Hot Water Press the ADV 1 button This will turn the Central Heating and or Hot Water ON if it is in an OF...

Page 12: ...the right of the display Fig 3 7 Using the HR Boost Function The HR function allows the user to have up to 3 hours of extra Central Heating or Hot Water without having to change the programme or use...

Page 13: ...time will change quicker if pressed continually 4 Press SET 1 once to move on to setting the DATE or press multiple times to return to RUN mode Setting the Date refer to g 4 1 Press the SET button 1...

Page 14: ...FF When the backlight is permanently OFF the backlight will turn ON for 15 seconds when or button is pressed then turn OFF automatically To change setting to permanently ON press SET repeatedly until...

Page 15: ...Installation Instructions...

Page 16: ...Technical Data 10...

Page 17: ...th throughout the system If the unit is tted to a metal surface IT IS ESSENTIAL that the metal be earthed DO NOT use a surface mounting box NEVER t or remove the unit to a live wall plate Maintenance...

Page 18: ...ng surface will fully cover the back of the programmer 2 O er the back plate to the wall in the position where the programmer is to be mounted remembering that the back plate ts to the left side of th...

Page 19: ...tats etc are general representations only However the wiring detail can be applied to the corresponding model of most manufacturers e g Horstmann Honeywell Danfoss Randall Drayton ESi Controls etc 1 R...

Page 20: ...14 Wiring Diagram...

Page 21: ...er to Setting the Backlight page 9 5 Leave these installation instructions with customer for reference Fitting the Programmer Loosen the two captive retaining screws on the bottom of the back plate No...

Page 22: ...day programming options as set up by the installer can also be veri ed at this stage by how the Monday to Sunday indicators are displayed In the interests of continuous product improvement we reserve...

Page 23: ......

Page 24: ...Version 3 1 ESi Controls Limited sales esicontrols co uk www esicontrols co uk...

Reviews: