Level 3, red LED: New state or after long operating pause 

In the new state or after a long operating pause, the sensor starts with a warm-up time of approx. 15 hours. 
During this time, the red LED flashes and a constant 0 ppm air quality is output via the 1-Wire interface. 
 

Level 2, yellow LED: Power interruption of several hours 

After a power interruption of a few hours or days, the sensor starts with a warm-up time of approx. 2 hours. 
During this time, the yellow LED flashes and 0 ppm air quality is constantly evaluated via the 1-Wire 
interface. 
 

Level 1, no LED-display: brief power interruption 

After brief voltage interruptions, the sensor starts normal operation directly. 
The sensor automatically switches to normal operation after completion of the warm-up phase. 
 
A light sensor is installed in the area of the upper ventilation opening, which automatically switches off the 
LEDs when it is dark. This does not affect the sensor function. The brightness sensor cannot be read out. 
 

Calibration / Adjustment 

The air quality sensor is delivered with factory settings. During the first day of operation, the air quality 
sensor calibrates itself automatically several times. To support automatic calibration, expose the sensor to 
fresh air several times (at least 15 minutes fresh air at 18 - 25°C). After a few adjustment cycles, the 1-Wire 
Multisensor Pro I delivers real air quality values. 
Calibration starts automatically or can be started by pressing the calibration button for at least 2 seconds. 
The calibration process starts with a slow flashing of the red LED. This signals that you should move away 
from the sensor and that the calibration process will start shortly. 
During the calibration process, the red LED flashes rapidly.  After the calibration has been completed, the 
sensor automatically switches to normal operation.  
The sensor is very sensitive and already reacts to the presence of people, so stay away from the sensor 
during calibration.  
Due to the system, the air quality sensor is subject to low aging, which is compensated by annual manual 
and automatic calibration. 

Note: Please remove yourself at the beginning of the calibration process. Your presence may cause 
the sensitive sensor to record incorrect calibration values. 
 

10 

Night function for LED “traffic light” 

If the calibration button is pressed for at least 10 seconds, the night function for the LED traffic light is 
permanently activated.  
If the night function is activated, the LED display is switched off by an internal light sensor in darkness in order, for 
example, to be able to sleep undisturbed during the night. The night function has no influence on other functions 
of the device. 
For details, see chapter "LED Display" earlier in this manual. Press the CAL button again for at least 10 seconds 
to permanently deactivate the night function. 
In the delivery state, the night function for the LED traffic light is not active, which means that the LED traffic light 
illuminates independently of the ambient brightness. 
 

11 

Software / Control 

The 1-Wire Multisensor Pro I is being read out per 1-Wire commands for the DS2438 modules. The sensor is 
supported by many systems such as ESERA Station, Loxone, IP-Symcon, OWFS, FHEM (Linux) or 
microcontroller applications. 
 
For ESERA 1-Wire Multisensors of the Pro series no elaborate formulas are necessary. 
A sensor controller within the Multisensor takes over the preprocessing of all measured values and thereby 
enormously simplifies the integration into 1-wire systems. The measured values are no longer dependent on 
the operating voltage of a 1-Wire Multisensor. 
 
The values measured by the sensor are assigned to the standard DS2438 module values as follows: 
VDD = operating voltage (5V), VAD = rel. humidity, Xsense = air quality. 
 
 
 
 
 

Summary of Contents for Multisensor Pro I

Page 1: ...red a professional and highly accurate multi sensor Due to the new technology of the ESERA 1 Wire Pro sensors the accuracy of humidity measurements is on average 200 300 higher compared to most standard sensors on the market In addition the evaluation of the delivered measured values is enormously simplified The 1 Wire Multisensor Pro enables simple climate monitoring of all rooms and buildings Th...

Page 2: ...zes ESERA chips sensors and actuators starts suitable libraries and outputs fully formatted data The Auto E Connect functionality will be available from mid 2020 via 1 Wire Controllers 1 Wire Gateways and 1 Wire ECO from ESERA available Further information on ESERA Auto E Connect can be found on the ESERA website ESERA Config Tool 3 or in the download area for this article in the ESERA Webshop 4 T...

Page 3: ... the LED display may be permanently off Table 7 1 8 Commissioning and warm up A calibration of the temperature and humidity sensor is not necessary The air quality sensor is pre calibrated After applying the supply voltage the integrated sensor controller checks the warm up time after which the air quality sensor starts The three possible stages of the warm up phases are indicated by the three LED...

Page 4: ...hat the calibration process will start shortly During the calibration process the red LED flashes rapidly After the calibration has been completed the sensor automatically switches to normal operation The sensor is very sensitive and already reacts to the presence of people so stay away from the sensor during calibration Due to the system the air quality sensor is subject to low aging which is com...

Page 5: ...r no _module no _data record voltage VCC V 1_OWD1_3 850 controller no _module no _data record rel humidity rF example 85 0 1_OWD1_4 1200 controller no _module no _data record dew point C example 12 00 C 1_OWD1_4 80000 controller no _module no _data record air quality ppm CO2 example 800 00 ppm Further information for options and commands can be found in the latest available documentation for 1 Wir...

Page 6: ... 8 1 Wire networks can be set up in star or tree cabling of approx 30 80m in total We recommend the use of CAT 5 7 network cables for the installation You will find a recommendation for cable assignment in the download section of this article Shielded cable e g CAT5 or CAT6 cable should be used in smart homes commercial buildings and industrial environments This ensures very good system stability ...

Page 7: ...During installation and handling of components which later have mains potential on their parts the relevant VDE regulations must be observed Devices that are to be operated at a voltage greater than 35 VDC 12mA may only be connected by a qualified electrician and put into operation Commissioning may only be realized if the circuit is built into a contact proof housing If measurements with an open ...

Page 8: ...0 www esera de 11151 V2 0 R1 0 Manual Page 8 of 8 Moreover from their appearance on ESERA GmbH webpages it cannot be concluded that designations logos names and trademarks are free of commercial property rights ESERA and Auto E Connect are registered trademarks of ESERA GmbH 25 Contact ESERA GmbH Adelindastrasse 20 87600 Kaufbeuren GERMANY Tel 49 8341 999 80 0 Fax 49 8341 999 80 10 www esera de in...

Reviews: