esera automation Multisensor Pro I User Manual Download Page 2

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH, ESERA-Automation 2020 

www.esera.de 

11151 V2.0 R1.0  Manual 

Page 2 of 8 

 
 
Thanks to the generous ventilation openings, the 1-Wire Multisensor Pro I very directly detects the ambient 
conditions in rooms. 
The 1-Wire Multisensor Pro I has a warm-up time for the air quality value. With a new 1-Wire Multisensor, 
this warm-up time is approx. 15 hours. After initial start-up, this is reduced to minutes or hours, depending on 
how long the Multisensor was without power. The warm-up phase is indicated by the red LED flashing. 
During the warm-up period, the air quality is output with the value 0. For further details, see chapter 
“commissioning and warm-up”. 
The 1-Wire Multisensor Pro I is equipped with screw terminals for the electrical connection of the 1-Wire bus 
interface and can be operated in standard mode (3 cables for ground, data and 5V). 
Due to the use of high-quality internal sensors with 12-bit resolution, the 1-Wire Multisensor Pro II delivers 
very accurate values for temperature, relative humidity and air quality. In addition, the evaluation of the 
delivered measured values is enormously simplified. 
 

Auto-E-Connect® Support 

The ESERA 

Auto-E-Connect®

 1-Wire Plug and Play system will be used for the  

1-Wire Bus supported. This enables fully automatic configurations of 1-Wire sensors 
and actuators on the 1-Wire bus. It is optimized for industrial applications and 
enables significant added value beyond the sensor and chip data. 
The Auto-E-Connect function automatically recognizes ESERA chips, sensors and actuators, starts suitable 
libraries and outputs fully formatted data. 
The Auto-E-Connect functionality will be available from mid 2020 via 1-Wire Controllers, 1-Wire Gateways and  
1-Wire ECO from ESERA available. 
Further information on ESERA Auto-E-Connect can be found on the ESERA website, ESERA Config-Tool 3, 
or in the download area for this article in the ESERA Webshop

 

 

Technical data 

Function:  

Multisensor for temperature and rel. humidity and air quality, 

 

monitoring of operating voltage 

Temperature sensor: 

Precise digital temperature sensor with 12 Bit measurement resolution 

Range of measuring temp.:   -40°C to +60°C (sensor element: -40°C to +85°C) 
Accuracy temperature: 

0,3° in the range of -10°C - 60°C (more accurate than the DS18B20 sensor) 

Resolution: 

12 Bit, 0,06°C/Bit depending on selected resolution 

 
Humidity sensor: 

Capacitive digital humidity sensor with high accuracy 

Range of measuring hum.:  0-100% rel. humidity 
Accuracy humidity: 

+/-3 % in the range of 10-85% rel. humidity 

Data output: 

0-10V equates 0-100% rel. humidity, 0,1V = 1% rF 

 
Air quality sensor (VOC): 

Mixed gas sensor (VOC) 

Range of measuring: 

400 - 1800 ppm (CO2 equivalent) 

Accuracy: 

+/- 10%, depending on air composition 

Data output: 

30-250mV equates 400-2900ppm, 1mV output voltage equates 11,6ppm.  
Min. output value: 30,51mV equates 405ppm. 

 
1-Wire connection: 

– conductor connection (data, ground and 5V, parasitic operation not 

supported) 

Connection: 

Screw terminals 

1-Wire interface 

Basis DS2438 

Operation voltage: 

5 V= (+10%/-20%) 

Current consumption: 

ca. 45mA 

Connection: 

Screw terminals 

 

Ambient conditions

 

Protection system: 

IP20 

Protection class: 

III 

Operation temperature for temperature sensor and rel. Humidity sensor:  

-25°C to 50°C, (limitation of the max. temperature by rel. humidity sensor and 

sensor-housing) 

Air quality sensor: 

0 to 50°C 

Rel. humidity: 

 

5 - 95% (non-condensing) 

Storage temperature: 

-25 to 50°C  

Outer dimensions: 

71 x 71 x 32mm (LxWxH) 

Summary of Contents for Multisensor Pro I

Page 1: ...red a professional and highly accurate multi sensor Due to the new technology of the ESERA 1 Wire Pro sensors the accuracy of humidity measurements is on average 200 300 higher compared to most standard sensors on the market In addition the evaluation of the delivered measured values is enormously simplified The 1 Wire Multisensor Pro enables simple climate monitoring of all rooms and buildings Th...

Page 2: ...zes ESERA chips sensors and actuators starts suitable libraries and outputs fully formatted data The Auto E Connect functionality will be available from mid 2020 via 1 Wire Controllers 1 Wire Gateways and 1 Wire ECO from ESERA available Further information on ESERA Auto E Connect can be found on the ESERA website ESERA Config Tool 3 or in the download area for this article in the ESERA Webshop 4 T...

Page 3: ... the LED display may be permanently off Table 7 1 8 Commissioning and warm up A calibration of the temperature and humidity sensor is not necessary The air quality sensor is pre calibrated After applying the supply voltage the integrated sensor controller checks the warm up time after which the air quality sensor starts The three possible stages of the warm up phases are indicated by the three LED...

Page 4: ...hat the calibration process will start shortly During the calibration process the red LED flashes rapidly After the calibration has been completed the sensor automatically switches to normal operation The sensor is very sensitive and already reacts to the presence of people so stay away from the sensor during calibration Due to the system the air quality sensor is subject to low aging which is com...

Page 5: ...r no _module no _data record voltage VCC V 1_OWD1_3 850 controller no _module no _data record rel humidity rF example 85 0 1_OWD1_4 1200 controller no _module no _data record dew point C example 12 00 C 1_OWD1_4 80000 controller no _module no _data record air quality ppm CO2 example 800 00 ppm Further information for options and commands can be found in the latest available documentation for 1 Wir...

Page 6: ... 8 1 Wire networks can be set up in star or tree cabling of approx 30 80m in total We recommend the use of CAT 5 7 network cables for the installation You will find a recommendation for cable assignment in the download section of this article Shielded cable e g CAT5 or CAT6 cable should be used in smart homes commercial buildings and industrial environments This ensures very good system stability ...

Page 7: ...During installation and handling of components which later have mains potential on their parts the relevant VDE regulations must be observed Devices that are to be operated at a voltage greater than 35 VDC 12mA may only be connected by a qualified electrician and put into operation Commissioning may only be realized if the circuit is built into a contact proof housing If measurements with an open ...

Page 8: ...0 www esera de 11151 V2 0 R1 0 Manual Page 8 of 8 Moreover from their appearance on ESERA GmbH webpages it cannot be concluded that designations logos names and trademarks are free of commercial property rights ESERA and Auto E Connect are registered trademarks of ESERA GmbH 25 Contact ESERA GmbH Adelindastrasse 20 87600 Kaufbeuren GERMANY Tel 49 8341 999 80 0 Fax 49 8341 999 80 10 www esera de in...

Reviews: