background image

All rights reserved. Reproduction as well as electronic duplication of this user manual, complete or in part, requires the written consent of 
ESERA-Automation or E-Service GmbH. Errors and technical modification subject to change.

 



ESERA-Automation, E-Service GmbH 2019

 

www.esera.de 

11233 V1.0 R1.1 Manual 

           Page 6 of 7                                   

13 

Assembly 

The mounting place must be protected against moisture. The module may only be used in dry indoor rooms or in 
protected outside areas. The device is designed for fixed installation within a switching cabinet. 

 

14 

Disposal instructions  

Do  not  dispose  this  device  in  the  household  waste.  Electronic  devices  must  be  disposed  in 
accordance  with  directives  for  disposing  of  waste  electrical  and  electronic  equipment  at  local 
collection points for electronic waste material. 

 

15 

Safety Instructions 

When using products that come into contact with electrical voltage, the valid VDE regulations must be 
observed, especially VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860 

 

During final works and wiring works power has to be de-connected. 

 

Before opening the device, always unplug and make sure that the unit is disconnected from the mains. 

 

Components, modules or devices may only be put into service if they are mounted in a contact proof housing. During 
installation they must not have power applied. 

 

Tools may only be used on devices, components or assemblies when it is certain that the devices are disconnected 
from the power supply and electrical charges stored in the components inside the device have been discharged. 

 

Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults or 
breaks. 

 

If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty cable 
has been replaced. 

 

When using components or modules it is absolutely necessary to comply with the requirements set out in the 
accompanying description specifications for electrical quantities. 

 

If the available description is not clear to the non-commercial end-user what the applicable electrical characteristics 
for a part or assembly are, how to connect an external circuit, which external components or additional devices can 
be connected or which values these external components may have, a qualified electrician must be consulted. 

 

It must be examined generally before the commissioning of a device, whether this device or module is basically 
suitable for the application in which it is to be used. 

 

In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary. 

 

For operational and connection errors outside of our control, we assume no liability of any kind for any resulting 
damage. 

 

Kits should be returned without their housing when not functional with an exact error description and the 
accompanying instructions. Without an error description it is not possible to repair the device. For time-consuming 
assembly or disassembly of cases charges will be invoiced. 

 

During installation and handling of components which later have mains potential on their parts, the relevant VDE 
regulations must be observed. 

 

Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified 
electrician and put into operation. 

 

Commissioning may only be realized if the circuit is built into a contact proof housing. 

 

If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be installed 
upstream or a suitable power supply can be used.  

 

After installing the required tests according to DGUV / regulation 3 (German statutory accident insurance, 

https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance

) must be carried out. 

 

16 

Warranty 

ESERA-Automation (E-SERVICE GmbH) guarantees that the goods sold at the time of transfer of risk to be free from material 
and workmanship defects and have the contractually assured characteristics. The statutory warranty period of two years 
begins from date of invoice. The warranty does not extend to the normal operational wear and normal wear and tear. 
Customer claims for damages, for example, for non-performance, fault in contracting, breach of contractual obligations, 
consequential damages, damages for tort and other legal grounds are excluded. Excepting to this, ESERA-Automation 
accepts liability for the absence of a guaranteed quality resulting from intent or gross negligence. Claims made under the 
Product Liability Act are not affected. If defects occur for which the ESERA-Automation is responsible, and in the case of 
replacement goods, the replacement is faulty, the buyer has the right to have the original purchase price refunded or a 
reduction of the purchase price. ESERA-Automation accepts liability neither for the constant and uninterrupted availability of 
ESERA-Automation or for technical or electronic errors in the online offer. 

 

We develop our products further and we reserve the right to make changes and improvements to any of the products 
described in this documentation without prior notice. If you need documentation or information about older product versions, 
contact us by email a

[email protected]

 

 
 
 
 
 
 
 
 

Summary of Contents for 11233

Page 1: ... New with a DS2408 interface 1 Introduction Before you start assembling the Dual Switch Module and before you take the device into operation please read these assembly and operating instructions carefully to the end especially the section referring to the safety notes 2 Product description With the Dual Switch Module it is possible to connect direct power consumers and alternative power consumers ...

Page 2: ... Wire component DS2413 Dual I O Supply voltage 12VDC 10 Power consumption12V Idle mode no output relay active approx 6mA both output relays are active approx 75mA in normal mode approx 40mA in power saving mode Button interface 2 input for button make contact no external power allowed Connection Screw terminals up to 2 5qmm wire cross section 4 Ambient conditions Temperature operation 0 C up to 50...

Page 3: ... consent of ESERA Automation or E Service GmbH Errors and technical modification subject to change ESERA Automation E Service GmbH 2019 www esera de 11233 V1 0 R1 1 Manual Page 3 of 7 Art No 11233 6 Connection Example The following example shows 1 Wire Controller or 1 Wire Gateway Dual Digital Output and 8 channel digital input ...

Page 4: ... button interface to control on off light commands For connection regular light switches of all manufacturers can be used Within the module a µ controller takes over the query of the buttons the 1 Wire interface and the control of the relays Flank control is used to query buttons and 1 Wire component The switching status of the relays can be set via the external and internal buttons Relays can als...

Page 5: ...e switched to active add up the output values Example Output value 1 2 3 Permitted output values for 1 Wire digital outputs 0 3 Command SET OWD OUTH OWD Number Output Value Example set owd outh 2 3 OWD Number 2 outputs 1 and 2 will be switched to active After switching the output latest status will be output as confirmation 11 3 Data output 1 Wire Controller 1 Wire Gateway For the Dual Switch Modu...

Page 6: ...e used In case of doubt consultation with experts or the manufacturer of the components used is absolutely necessary For operational and connection errors outside of our control we assume no liability of any kind for any resulting damage Kits should be returned without their housing when not functional with an exact error description and the accompanying instructions Without an error description i...

Page 7: ...le legally protected designations of their respective owners and are hereby recognized as such by us The mention of these designations logos names and trademarks is made for identification purposes only and does not represent a claim any kind on the part of ESERA Automation Andreas Geisler on these designations logos names and trademarks Moreover from their appearance at ESERA Automation webpages ...

Reviews: