background image

 

 

 

All rights reserved. Reproduction as well as electronic duplication of this user manual, complete or in part, requires the written consent of 
ESERA-Automation or E-Service GmbH. Errors and technical modification subject to change.

 



ESERA-Automation, E-Service GmbH 2019 

www.esera.de 

11233 V1.0 R1.1 Manual 

           Page 7 of 7 

Art. No. 11233 

17 

Trademarks 

All mentioned designations, logos, names and trademarks (including those which are not explicitly marked) are trademarks, 
registered trademarks or other copyright or trademark or title legally protected designations of their respective owners and are 
hereby recognized as such by us. The mention of these designations, logos, names and trademarks is made for identification 
purposes only and does not represent a claim any kind on the part of ESERA-Automation, Andreas Geisler on these 
designations, logos, names and trademarks. Moreover, from their appearance at ESERA-Automation webpages it cannot be 
concluded that designations, logos and names are free of commercial property rights. 
ESERA is a registered trademark of E-Service GmbH. 
 

18 

 Contact 

ESERA-Automation 
E-Service GmbH 
Adelindastrasse 20 
87600 Kaufbeuren 
Tel.: +49 8341 999 80-0 
Fax: +49 8341 999 80-10 

www.esera.de

 

[email protected]

 

WEEE-Nummer: DE30249510

 

 

Summary of Contents for 11233

Page 1: ... New with a DS2408 interface 1 Introduction Before you start assembling the Dual Switch Module and before you take the device into operation please read these assembly and operating instructions carefully to the end especially the section referring to the safety notes 2 Product description With the Dual Switch Module it is possible to connect direct power consumers and alternative power consumers ...

Page 2: ... Wire component DS2413 Dual I O Supply voltage 12VDC 10 Power consumption12V Idle mode no output relay active approx 6mA both output relays are active approx 75mA in normal mode approx 40mA in power saving mode Button interface 2 input for button make contact no external power allowed Connection Screw terminals up to 2 5qmm wire cross section 4 Ambient conditions Temperature operation 0 C up to 50...

Page 3: ... consent of ESERA Automation or E Service GmbH Errors and technical modification subject to change ESERA Automation E Service GmbH 2019 www esera de 11233 V1 0 R1 1 Manual Page 3 of 7 Art No 11233 6 Connection Example The following example shows 1 Wire Controller or 1 Wire Gateway Dual Digital Output and 8 channel digital input ...

Page 4: ... button interface to control on off light commands For connection regular light switches of all manufacturers can be used Within the module a µ controller takes over the query of the buttons the 1 Wire interface and the control of the relays Flank control is used to query buttons and 1 Wire component The switching status of the relays can be set via the external and internal buttons Relays can als...

Page 5: ...e switched to active add up the output values Example Output value 1 2 3 Permitted output values for 1 Wire digital outputs 0 3 Command SET OWD OUTH OWD Number Output Value Example set owd outh 2 3 OWD Number 2 outputs 1 and 2 will be switched to active After switching the output latest status will be output as confirmation 11 3 Data output 1 Wire Controller 1 Wire Gateway For the Dual Switch Modu...

Page 6: ...e used In case of doubt consultation with experts or the manufacturer of the components used is absolutely necessary For operational and connection errors outside of our control we assume no liability of any kind for any resulting damage Kits should be returned without their housing when not functional with an exact error description and the accompanying instructions Without an error description i...

Page 7: ...le legally protected designations of their respective owners and are hereby recognized as such by us The mention of these designations logos names and trademarks is made for identification purposes only and does not represent a claim any kind on the part of ESERA Automation Andreas Geisler on these designations logos names and trademarks Moreover from their appearance at ESERA Automation webpages ...