background image

*if the sensor or actuator supports Auto-E-Connect. For details, please refer to the operating instructions of the sensor or actuator. 
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH 2021 

www.esera.de 

11216 V5.0 R1.0 Manual 

Page 8 of 9 

 

13 

Assembly 

The mounting location must be protected against moisture. The device may only be used in dry indoor areas and 
in protected outdoor areas. 
The device is intended for mounting inside a control cabinet as a stationary device.  
 

14 

Disposal note  

Do not dispose of the unit in household waste! Electronic devices must be disposed of at 
the local collection points for electronic devices in accordance with the Directive on  
Waste Electrical and Electronic Equipment! 
 

15 

Safety instructions 

When using products that come into contact with electrical voltage, the valid VDE regulations must be observed, especially 
VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860 

 

All final or wiring work must be carried out with the power turned off. 

 

Before opening the device, always unplug or make sure that the unit is disconnected from the mains. 

 

Components, modules or devices may only be put into service if they are mounted in a contact proof housing. During 
installation they must not have power applied. 

 

Tools may only be used on devices, components or assemblies when it is certain that the devices are disconnected 
from the power supply and electrical charges stored in the components inside the device have been discharged. 

 

Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults or 
breaks. 

 

If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty cable 
has been replaced. 

 

When using components or modules it is absolutely necessary to comply with the requirements set out in the 
accompanying description specifications for electrical quantities. 

 

If the available description is not clear to the non-commercial end-user what the applicable electrical characteristics for 
a part or assembly are, how to connect an external circuit, which external components or additional devices can be 
connected or which values these external components may have, a qualified electrician must be consulted. 

 

It must be examined generally before the commissioning of a device, whether this device or module is basically 
suitable for the application in which it is to be used. 

 

In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary. 

 

For operational and connection errors outside of our control, we assume no liability of any kind for any resulting 
damage. 

 

Kits should be returned without their housing when not functional with an exact error description and the 
accompanying instructions. Without an error description it is not possible to repair. For time-consuming assembly or 
disassembly of cases charges will be invoiced. 

 

During installation and handling of components which later have mains potential on their parts, the relevant VDE 
regulations must be observed. 

 

Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified 
electrician and put into operation. 

 

Commissioning may only be realized if the circuit is built into a contact proof housing. 

 

If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be installed 
upstream or a suitable power supply can be used.  

 

After installing the required tests according to DGUV / regulation 3 (German statutory accident insurance  

https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance

must be carried out. 

 

16 

Warranty 

ESERA GmbH guarantees that the goods sold at the time of transfer of risk to be free from material and workmanship 
defects and have the contractually assured characteristics. The statutory warranty period of two years begins from date of 
invoice. The warranty does not extend to the normal operational wear and normal wear and tear. Customer claims for 
damages, for example, for non-performance, fault in contracting, breach of secondary contractual obligations, 
consequential damages, damages resulting from unauthorized usage and other legal grounds are excluded. Excepting to 
this, ESERA GmbH accepts liability for the absence of a guaranteed quality resulting from intent or gross negligence. 
Claims made under the Product Liability Act are not affected. 
If defects occur for which ESERA GmbH is responsible, and in the case of replacement goods, the replacement is faulty, 
the buyer has the right to have the original purchase price refunded or a reduction of the purchase price. ESERA GmbH 
accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical or electronic 
errors in the online offer. 
 We develop our products further and we reserve the right to make changes and improvements to any of the products 
described in this documentation without prior notice. If you need documentation or information about older product 
versions, contact us by email a

[email protected].

  

 

 

 

Summary of Contents for 11216

Page 1: ...of 9 Art No 11216 User Guide 8 fold Digital Input for 1 Wire Bus 8 inputs for 10 30V DC signals e g for switches reed contacts or other digital sensors LED displays for input status and supply voltage Inputs can be activated by manual operation DIN rail housing for control cabinet installation Connection via screw terminals Simple software integration 1 Wire interface DS2408 commands Housing color...

Page 2: ...ion of the Module only a 2V supply voltage is necessary For this we recommend the use of one of our 1 Wire Hub module 2 Technical Data Number and Type 8 inputs for DC voltage signals 10 30VDC Input voltage max 30 VDC max 8mA low level 5V high level 10 30V Filter Software filter against switch bounce 30 ms delay LED displays 10 LEDs Power LED Status LED 8 x Input Input LED lights up at status high ...

Page 3: ...rmatted data is output The Auto E Connect functionality will be available for the ECO Controller and ESERA Station 200 Pro from 2021 Auto E Connect Level I OWD Detect detection of new sensors and actuators and automatic start of adapted libraries Auto E Connect Level II Visualisation product data reading out and visualising of the Auto E Connect and manufacturer data of sensors and actuators e g a...

Page 4: ...ound 2 1 Wire 3 12V voltage Note The module may only be operated at the voltages and under the ambient conditions specified for it The operating position of the device is arbitrary The modules may only be commissioned by a qualified electrician For further information on the operating conditions see the following instructions under Operating conditions Note on switching loads When switching capaci...

Page 5: ... as electronic duplication of this user guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH 2021 www esera de 11216 V5 0 R1 0 Manual Page 5 of 9 Art No 11216 8 Connection example Here is a connection example with 1 Wire Controller or 1 Wire Gateway Dual Digital Output and 8 fold Digital Input ...

Page 6: ...n press for 2 seconds activation of Manual Mode for setting the inputs after that selection of the input to be set by pressing briefly Pushbutton 2 ON OFF the pushbutton has a double function input on off in Manual Mode by pressing briefly press for 2 seconds deactivates Manual Mode for all manually set inputs 10 Software Control The 1 Wire interface of the module is read out via 1 Wire command fo...

Page 7: ... linear topology can be compared like pearls on a pearl necklace The data line should be laid from one device to the next without T joints Furthermore the type of cable used can also be mentioned here We recommend for the cabling CAT5 or CAT6 network cable It is also possible to use J Y St Y telephone cables and KNX cables Longer cable runs are possible with CAT5 versus CAT7 cables With twisted pa...

Page 8: ...lly suitable for the application in which it is to be used In case of doubt consultation with experts or the manufacturer of the components used is absolutely necessary For operational and connection errors outside of our control we assume no liability of any kind for any resulting damage Kits should be returned without their housing when not functional with an exact error description and the acco...

Page 9: ...r titles or legally protected designations of their respective owners and are hereby expressly recognized as such by us The mention of these designations logos names and trademarks is made for identification purposes only and does not represent a claim of any kind on the part of ESERA GmbH on these designations logos names and trademarks Moreover from their appearance on ESERA GmbH webpages it can...

Reviews: