Insert the DC head of the attached power adapter into the power port on the back of the 

instrument, connect the power adapter to the AC110-220V socket, the POWER green indicator 

light is on, and the instrument is running normally.

06

Installation

Use M6 screws and nuts to fix the bottom bracket of the fan at an appropriate position that 

needs to eliminate static electricity. 

When using more than two ionizers, make sure to keep a distance of at least 100mm between 

the two. 

The distance from the air outlet needs to be at least 100mm away from static objects, and 

reverse charging may occur within 100mm.

The ionizer is at least 300mm away from the metal conductor, and the air inlet is at least 

150mm away from the wall and other objects.

07

Installation Method

Notice: Ionizer has to be ground properly to make sure ion output automatic balance

Installation Diagram

08

Testing Method

Equipment name: The company uses ME-288B rechargeable flat panel tester (CPM). 

The test instrument must be well grounded, and the ionizer under test must be well grounded.

The ion blowing port of the desktop ionizer is centered on the flat tester and tested at different 

distances such as 30cm, 60cm, and 90cm.

The test is carried out at maximum air volume and no dust filter.

Test the two performance parameters of bias voltage and dissipation time. 

Factory test method:

Summary of Contents for DC0601C

Page 1: ...aging It can also be installed in equipment to provide rapid static elimination in a limited space to solve static electricity generated during high end manufacturing processes Steady state DC ionization technology has the following advantages Compact body design light weight Both sides buckles design can lock the blowing angle Stable ion balance Longer cleaning and maintenance intervals No need f...

Page 2: ...bracket Compact Ionizer Eliminate static electricity speed 30CM 3 0sec 20V ion balance 30cm distance Suction type design fan at the front and discharge emitter at the back Both sides buckles design The discharge emitter can be cleaned with alcohol cotton through the rear grille Tungsten material discharge needle Alarm and equipment monitoring interface DC24V Input Meet cleanliness requirements Fea...

Page 3: ...e Operating Env Dimension Net weight Case material Warranty Certification DC24V signal will be output 0 7m min Below 0 004ppm distance 150mm 0 40 C 20 75 RH non condensing 117 83 64mm Without bracket 138 115 64mmWith bracket H W D Aprpox 0 4Kg ABS Shell aluminum alloy oxide bracket One year POWER Operation indicator ALARM Alarm Indicator ...

Page 4: ...charging may occur within 100mm The ionizer is at least 300mm away from the metal conductor and the air inlet is at least 150mm away from the wall and other objects 07 Installation Method Notice Ionizer has to be ground properly to make sure ion output automatic balance Installation Diagram 08 Testing Method Equipment name The company uses ME 288B rechargeable flat panel tester CPM The test instru...

Page 5: ...imum the dissipation time from 1000V 100V Different environment test results are different the above is the reference data please test according to the actual use environment 20V 300 2 5S 3 0S 600 7 5S 8 9S 900 15 5S 17 6S Temperature23 3O C Humidity50 5 After the discharge emitter is used for a long time there will be dust and other pollutants in and around the discharge emitter Use cotton swabs ...

Page 6: ...oor design and manufacturing free maintenance will be provided Warranty Warranty Period The discharge emitter is a consumable part and is not covered by the warranty Breakage breakage or malfunction due to abnormal use Failure caused by changes or disassembly and maintenance by non maintenance personnel of our company Failures caused by natural force majeure factors such as fires natural disasters...

Reviews: