Insert the DC head of the attached power adapter into the power port on the back of the
instrument, connect the power adapter to the AC110-220V socket, the POWER green indicator
light is on, and the instrument is running normally.
06
Installation
Use M6 screws and nuts to fix the bottom bracket of the fan at an appropriate position that
needs to eliminate static electricity.
When using more than two ionizers, make sure to keep a distance of at least 100mm between
the two.
The distance from the air outlet needs to be at least 100mm away from static objects, and
reverse charging may occur within 100mm.
The ionizer is at least 300mm away from the metal conductor, and the air inlet is at least
150mm away from the wall and other objects.
07
Installation Method
Notice: Ionizer has to be ground properly to make sure ion output automatic balance
Installation Diagram
08
Testing Method
Equipment name: The company uses ME-288B rechargeable flat panel tester (CPM).
The test instrument must be well grounded, and the ionizer under test must be well grounded.
The ion blowing port of the desktop ionizer is centered on the flat tester and tested at different
distances such as 30cm, 60cm, and 90cm.
The test is carried out at maximum air volume and no dust filter.
Test the two performance parameters of bias voltage and dissipation time.
Factory test method: