Overview
VME-PMC-CADDY/2
Hardware-Manual • Doc.-No.: V.1915.21 / Rev. 1.0
Page 9 of 43
1.4 Technical Data
1.4.1 General Technical Data
VMEbus-Interface
IEEE 1014 / Rev. D
Master or Slave functionality
Base address
geographical addressing
Address modifier
standard supervisory and non-privileged data access,
extended supervisory and non-privileged data access,
short supervisory and non-privileged access
VMEbus access
- Legacy-protocols supporting the preservation of existing VME-
systems
- VME64 extensions
- 2eVME- and 2eSST protocols
VMEbus back plane
compatible to VME32, VME64 and VME64x back planes
Ambient temperature
range
Standard:
0...50
/
C
(order no.: V.1915.02/.11)
Extended
temperature range:
-40...+85
/
C (order no.: V.1915.03 /.13)
Conduction cooled: -40...+85
/
C (order no.: V.1916.02 /.11)
Humidity
max. 90%, non-condensing
Connectors
P1, P2 -
160-pin VG-connector according to DIN 41612
in compliance with VME64 extension
P0 -
95-pin I/O-connector according to
IEC 1076-4-101
J11 to J24 - 64-pin PMC-socket connector:
J11, J12, J21, J22 -
PMC-address/data signals
J13, J23 -
PCI 64 signals
J14, J24 -
PMC I/O-signals
J15 -
114-pin XMC socket (optional)
X1940 -
10-pin har-link socket: 2x serial (RS232)
(not at VME-PMC-CADDY/2-CC)
Service- and diagnostic connector:
X1800 -
Socket connector 1x16: Debug CPU
X1801 -
Socket connector 1x7: JTAG-TSI148
X2120 -
Socket connector 1x7: JTAG-PCI
X2310 -
Socket connector 1x6: ISP-ADU848
Dimensions
160 mm x 233 mm
Slot format
6 U high / 4 HP wide