Manufacturer Specific Profile Area
Manual • Doc.-No.: C.3055.21 / Rev. 1.1
CAN-CBX-COM2
Page 96 of 125
¡
¡
¢
£ ¤
¥ ¦
¢
£ ¤
¥ ¦
¥ § ¨
¥ §
¨
¥ § ¨
8.12.2.2 Inhibit-Time
An overview of the communication parameters 2800
h
and 2900
h
is shown on page 95.
Parameter name
Inhibit-Time
Object index,
Sub-index
2800
h
, 01
h
(COM A)/
2900
h
, 01
h
(COM B)
Access mode
rw
Data type
unsigned 8
Value range
00...FF
h
Unit
ms
Default value
14
h
= 20 ms
Description:
The Parameter Inhibit-Time defines the waiting period between two transmission
cycles of serial data on the CAN bus.
The parameter Inhibit-Time defines how long the CAN controller waits after the last
successful transmission of CAN data, before another transmission is triggered. The
value is specified in [ms].
Fig. 25: Function of the parameter Inhibit-Time (parameter MaxChar = 1)