8.12.2 Serial Communication Parameter 2800
h
, 2900
h
The serial communication parameters of object 2800
h
and object 2900
h
are described together in this
chapter, because they are identically structured. The communication parameters of object 2800
h
are used
for interface COM A and the communication parameters of object 2900
h
are used for interface COM B.
8.12.2.1 Overview
COM A: 2800
h
COM B: 2900
h
Index
Sub-
index
Description
Value
range
Default
Value
Data type
Access
Mode
Save to
EEPROM
see
Page
2800
h
/
2900
h
0
Number of entries
10
h
10
h
unsigned 8
ro
no
-
1
Inhibit-Time
00...FF
h
14
h
unsigned 8
rw
yes
96
2
MaxChar_MinChar
00...FF
h
11
h
unsigned 8
rw
yes
97
3
Serial_Baudrate
00...FF
h
22
h
(9600
Baud)
unsigned 8
rw
yes
99
4
Serial_Mode
00...FF
h
73
h
unsigned 8
rw
yes
101
5
TxMinCharStart
00...FF
h
00
h
unsigned 8
rw
yes
105
6
Protocol
00...63
h
00
h
unsigned 8
rw
yes
106
7
Handshake_Off
00...FF
h
F6
h
unsigned 8
rw
yes
108
8
Handshake_On
10...FF
h
0A
h
unsigned 8
rw
yes
108
9
TxByRxTimeout
00...FF
h
00
h
unsigned 8
rw
yes
110
A
h
End_Char_1
00...FF
h
0D
h
unsigned 8
rw
yes
111
B
h
End_Char_2
00...FF
h
0A
h
unsigned 8
rw
yes
111
C
h
Special_Baudrates
0001...
07FF
h
0034
h
unsigned 16
rw
yes
112
D
h
RTR_T_Cycle_Time
0000...
FFFF
h
1388
h
unsigned 16
rw
yes
113
E
h
Tx_Cycle_Time
0000...
FFFF
h
0000
h
unsigned 16
rw
yes
114
F
h
Break_Code
0000...
FFFF
h
0000
h
unsigned 16
rw
yes
115
10
h
Break_Time_Factor
00...FF
h
0B
h
unsigned 8
rw
yes
116
Table 18: Overview of the parameters of object 2800
h