SLD-300 Semi-Conductive Refrigerant Leak Detector
Contents
:
1. General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page. 8
2. Main Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page. 8
3. Installing and Charging Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page. 9
4. operating features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page. 10
4.1 Battery Voltage Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page. 10
4.2 Automatic circuit / Reset feature . . . . . . . . . . . . . . . . . . . . . . . . . . . page. 10
4.3 Sensitivity Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page. 11
4.4 Sensor Status Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page. 11
4.5 Audible / Visual Alarms – Mute Feature . . . . . . . . . . . . . . . . . . . . . page. 11
5. Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page. 11
6. Detection method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page. 12
7. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page. 13
1. GENERAL DESCRIPTION
SLD-300 offers the greatest sensitivity and fastest response of any portable refrigerant detector available. This is
achieved through the employment of a high sensitive semi-conductive sensor combined with a sophisticated
microprocessor-controlled circuit. In addition to the supreme performance and functional advantages, it offers an
unique designed shape to provide greater ease of use and comfort.
2. MAIN FEATURES
•
Sensor type: Semi-conductive sensor
•
Minimum Sensitivity: 2g/yr (R134a)
•
Response time: <2s
•
Warm up time: <60s
•
Ambient Environment:
•
Temperature: 0°C - 50°C; humidity: <80%RH (non condensing)
•
Application of refrigerant: It will respond to all halogenated (including Chlorine of Fluorine) refrigerants. This
includes, but is not limited to:
CFCs
e.g.R12,R11,R500,R503 etc.
HCFCs e.g.R22,R123,R124,R502 etc.
HFCs e.g.R134a,R404a,R410a,R125 etc.
•
Display method: Red and blue LED indicator lights
•
One-touch reset and seven-level adjustable sensitivity
•
True mechanical pump provides instant response and fast clearing of interference gases
•
Battery level indication
•
Sensor failure indication
•
3.7V /Li /2200mAh rechargeable batteries
•
Unique shape design
•
Flexible stainless probe
SLD-300 LEAK DETECTOR OWNER'S MANUAL
9
SALVADOR ESCODA S.A.
®
Provença, 392 pl. 1 y 2
08025 BARCELONA
Tel. 93 446 27 80
Fax 93 456 90 32
CATÁLOGO TÉCNICO
www.salvadorescoda.com
MANUALES, CATÁLOGOS Y HOJAS TÉCNICAS: EN NUESTRA WEB