11. ADVANCED SYSTEMS.
11.1. Solar collector and boiler circulating pump control system.
10
Functions performed by the controller in the system:
–collector pump control
–central heating boiler circulating pump control system
Tips for parameters programming:
F10=1 (boiler T1 and collector T2 temp. measurement)
F11=temperature difference T2-T1 between the solar
collector and the boiler after reaching that, the collector's
pump switches on, for example 8 °C
F12=pump switching hysteresis, for example 2 C
F15=OFF
F16=In cloudy days, when solar energy is low, it is essential
to heat-up the boiler from the other source. This parameter
specifies the boiler temperature below which an external
heating source switches on, for example boiler circulating
pump. Setting, for example 40 °C.
F17=90min (external heating source switching delay)
F21=0; F29=COOL ; F50=0 ; F51=0 ; F52=0
°
F12=2
°C
F12=2
°C
6°C
8°C
Main
output
Time
Time
Temp.
0
1
10°C
Auxiliary
output
When T1<F16
1
T2-T1
Time
0
F11
Push the button
for 2 seconds.
Confirm the set with
Key.
Diode lights up.
Using
or button
set the desired
temperature value.
set
set
Diode lights off.
Remarks:
–to cancel the setting, press the button in any time
–the setting change can be limited by F13 and F14 parameters
Information:
To improve quick increasing or decreasing the settings values hold the or button
constantly for at least 1 sec.
Enter the menu holding
Key for 5 sec., Until:
Command
displays.
Using key confirm
the new parameter
value and return to the
parameters list.
Using
or key
choose the parameter
you want to change and
enter with
Key.
set
set
set
set
set
M
M
If the access is protected
Command
displays.
Using
, and
Buttons enter the
password and confirm
with key.
Using
or
button
set the desired
parameter value.
Finish programming
pressing button or
enter the ‘’End’’ command
and press key or wait
30 sec. without pressing
any button
Remarks:
- press button to cancel the parameter setting
Information:
Hold
or button for at least 1 sec. to improve quick increasing and decreasing of setting
values.
SC-20
T1 - boiler temperature sensor
T2 - fireplace temperature sensor
Collector pump and c.h. pump max. 400W 230V~
Power supply
230V~
20(8)A
8(2)A
T2
Pk
Pco
13 14 15 16
12
11
°C
M
set
°C
M
set
°C
M
set
M
set
M
set
°C
M
set
M
set
°C
M
set
M
set
Pc
Pb
T2
T1
M
set