Troubleshooting
PROBLEM
POSSIBLE CAUSE
SOLUTION
Air leak
Leak in the connection
Check the connection
The inflator works,
but no air is flowing
Obstruction in filters or in
air system
Clean the filters and
check the air source
No display
Flat battery
Recharge battery
Inflation does not start,
although the pressure is set
and the hose is connected
with tyre
Air hose improperly connected
Check the hose
connection, make sure
that no air leaks
T
i
re pressure is below
0.2 bar (3 psi)
Manual inflation
Err1
Pressure sensor broken
Power off, change
pressure sensor
Err2
Unstable pressure,
faulty hose connector
Replace hose connector or
re-connect hose to the t
i
re
Err3
Connected tyre pressure is
too high 12.5 bar (180 psi)
Stop inflating this t
i
re
Err4
Wrong connections at air inlet
and outlet
Refer to wiring diagram and
connect magnetic valve
accordingly
Err5
Battery low
Please recharge the battery
Err8
Air supply lower than set
inflate pressure
Stop inflating this t
i
re
8
8
Maintenance
The device does not require particular maintenance, routine check of the air connections
is suggested.
In the event that maintenance is required it should be carried out by qualified personnel.
Warranty Note
■
This unit must be used with clean dry air. Therefore an air filter and or water trap must
be used with this unit to ensure its continued reliability.
■
Moist air entering this unit will affect the pressure sensors and may cause the
electronics to fail.
■
Please ensure only airline systems with clean dry air are connected to this t
i
re inflator.
■
Product warranty will be void if moisture enters the t
i
re inflator.