background image

vi 

|

This page intentionally left blank. 

 

Summary of Contents for ETS-Lindgren 3107B

Page 1: ...Model 3107B Parallel Element E Field Generator User Manual...

Page 2: ...herein ETS Lindgren L P does not convey any license under its patent rights or the rights of others Copyright 1991 2011 by ETS Lindgren L P All Rights Reserved No part of this document may be copied b...

Page 3: ...Service Procedures 11 3 0 Specifications 13 Electrical Specifications 13 Physical Specifications Assembled 13 Typical Power Requirements at One Meter 14 Typical Test Setup Power Requirements 15 Typic...

Page 4: ...This page intentionally left blank iv...

Page 5: ...ns could result in minor personal injury and or property damage Included text gives proper procedures Warning Denotes a hazard Failure to follow instructions could result in SEVERE personal injury and...

Page 6: ...vi This page intentionally left blank...

Page 7: ...Hz frequency range in two bands Band 1 covers the frequency range from 10 kHz to 5 MHz and Band 2 covers 5 MHz to 30 MHz For portability the Model 3107B elements are easily attached and removed Attach...

Page 8: ...d minimum height is 94 cm 37 0 in This tripod can support up to an 11 8 kg 26 0 lb load 7 TR Tripod Constructed of PVC and fiberglass components providing increased stability for physically large ante...

Page 9: ...ation Bulletin included with your shipment for the following Warranty information Safety regulatory and other product marking information Steps to receive your shipment Steps to return a component for...

Page 10: ...This page intentionally left blank 10...

Page 11: ...lacement and Optional Parts ETS Lindgren may substitute a similar part or new part number with the same functionality for another part part number Contact ETS Lindgren for questions about part numbers...

Page 12: ...This page intentionally left blank 12...

Page 13: ...rn At one meter on centerline the field is a linearly polarized essentially homogenous E field E Field Capability See tables on page 14 and page 16 Maximum Power Capability 1000 Watts Connector Type N...

Page 14: ...14 Typical Power Requirements at One Meter See typical test setup on page 15...

Page 15: ...TYPICAL TEST SETUP POWER REQUIREMENTS 15...

Page 16: ...Typical Input Voltage Requirements at One Meter See typical test setup on page 17 16...

Page 17: ...TYPICAL TEST SETUP INPUT VOLTAGE REQUIREMENTS 17...

Page 18: ...18 Schematic for Model 3107B...

Page 19: ...enerator by rotating it clockwise into the plate until it is firmly connected 2 Attach the support base to the support rod by rotating it clockwise onto the rod until it is firmly connected 3 Attach t...

Page 20: ...signal source to determine the input voltage power applied The field strength capability is shown in the tables on page 14 and page 16 A field intensity monitor on the opposite side of the Model 3l07B...

Page 21: ...e ETS Lindgren warranty for your Model 3107B DURATION OF WARRANTIES FOR MODEL 3107B All product warranties except the warranty of title and all remedies for warranty failures are limited to one year P...

Reviews: