1. Model 
2. CE mark 
3.  Manufacturers  address  and  country 
of origin 
4. Logo and serial number 
5. Observe WEEE 
6. Year of manufacture 

 

6 Important safety instructions and warnings 

6.1 Before installation 

1. Do not use the product if the package is damaged. Contact Esco Medical or the local 
representative.  
2. Read the User manual completely before use.  
3. Always keep these instructions easily accessible near the device.  

6.2 During installation 

1.  Place this unit on a flat, hard and stable surface.  
2.  Never place the unit on a carpet or similar surfaces.   
3.  This unit is intended for indoor purpose only. 
4.  Lift the device carefully. All AVT-1

®

 

parts are heavy and may require additional 

people to move them around.     

5.  Float elements have to go into the hole on a tabletop 

– be careful not to squeeze 

fingers or drop the element through the hole.    

6.3 Post installation 

1.  Refer all servicing procedures to a qualified service personnel.  

7 Getting started 

Follow the guidelines in the safety instructions and warnings section. 
 

 If the device is going to be used in a clinical setting, clean and disinfect the 

device  before  use.  It  is  not  delivered  sterile  or  in  a  clinically  acceptable  clean 
state.  Consult  the  cleaning  instructions  section  in  this  manual  for  the  manufac-
turer’s recommended guidelines!  

Assembling Esco Medical AVT-1

®

.  

Summary of Contents for AVT-1

Page 1: ...Rev 1 8 Rx only Anti vibration Table AVT 1...

Page 2: ...s the right to make periodic minor design changes without obligation to notify any person or entity of such change Caution Federal law restricts this device to sale by or on the order of a licensed he...

Page 3: ...se note that only the serialized products products labelled with a distinct serial number and accessories are eligible for partial refund and or credit Non serialized parts and accessory items cables...

Page 4: ...other than Esco Medical IN NO EVENT SHALL ESCO MEDICAL LTD BE HELD LIABLE FOR CONSE QUENTIAL DAMAGES No warranty shall apply when damage is caused by any of the following Power failure surges or spike...

Page 5: ...original warranty covering your product becomes void when the tamper resistant Quality Seal is removed or broken without proper factory authorization In all cases breaking the tamper resistant Qualit...

Page 6: ...AVT 1 User Manual Rev 1 8 6 COMPONENTS UNAUTHORIZED REMOVAL OF THE INSTRUMENT COVER SHALL VOID THIS AND ANY OTHER EXPRESSED OR IMPLIED WARRANTIES...

Page 7: ...product 8 4 Accessories supplied 9 5 Safety symbols and labels 9 6 Important safety instructions and warnings 10 6 1 Before installation 10 6 2 During installation 10 6 3 Post installation 10 7 Gettin...

Page 8: ...nance to this equipment must be un dertaken by a qualified service personnel If the equipment must be relocated make sure it is fixed properly on a support stand or base and move it on a flat surface...

Page 9: ...s the microscope area The degree of improvement varies between instruments and locations depending on the amplitude and frequency of floor vibrations This product does not carry a CE mark Only those p...

Page 10: ...carpet or similar surfaces 3 This unit is intended for indoor purpose only 4 Lift the device carefully All AVT 1 parts are heavy and may require additional people to move them around 5 Float elements...

Page 11: ...le plate Figure 7 1 Leveling table legs Put on gloves Install the springs into the holes at the front and the back of the table A 3rd spring placed in the centre may be supplied for the use of a very...

Page 12: ...tops should be facing up Leave equal distance from the hole on all sides of the table plate Then place the top of the floating element stainless steel on the rubber parts again leaving equal distance...

Page 13: ...ween the attachment point on the microscope and the other side This can be achieved by strip ping the cable to the points and making sure that the cable forms an arch between the points If the cable i...

Page 14: ...be in the centre position of the hole Air should be all around the floater Loose tightening bolts Tighten four tightening bolts The spring system is not painted and has to be completely grease free t...

Page 15: ...ight 70 kg Material Powder painted mild steel Stainless steel Glass Float Size 540 340 Power consumption 115V 60Hz OR 230V 50Hz Recommended load weight 26 32 kg Damping coefficient 6 Hz 0 1 Amplitude...

Reviews: