background image

 

If the tower icon flashes, but does not set the time or the DCF tower does not appear at 
all, then please take note of the following: 

 

Recommended distance to any interfering sources like computer monitors or TV 
sets is a minimum of 1.5 - 2 meters. 

 

Within ferro-concrete rooms (basements, superstructures), the received signal is 
naturally weakened. In extreme cases, please place the unit close to a window 
and/or point its front or back towards the Frankfurt transmitter. 

 

During nighttime, the atmospheric disturbances are usually less severe and 
reception is possible in most cases. A single daily reception is adequate to keep the 
accuracy deviation below 1 second. 

 

MANUAL TIME SETTING: 

In case the Weather Station cannot detect the DCF-signal (for example due to 
disturbances, transmitting distance, etc.), the time can be manually set. The clock will 
then work as a normal Quartz clock. 
1. 

Press and hold the ALARM/SET key for around 3 seconds to enter the set mode. 

2. 

Press the ALARM/SET key again to enter the Manual Time setting mode. The hour 
digits start flashing. 

3. 

Use the MIN/MAX/+ key or -/HISTORY key to set the hour.  

4. 

Press again the ALARM/SET key to confirm the set value. The minute digits start 
flashing. 

5. 

Use the MIN/MAX/+ key or -/HISTORY key to set the minutes. 

6. 

Now press the ALARM/SET key to enter the Time zone setting mode.   

 

Note: 

The unit will still try to receive the signal every hour despite it being manually set. When it 
does receive the signal, it will change the manually set time into the received time. During 
reception attempts the DCF tower icon will flash. If reception has been unsuccessful, then 
the DCF tower icon will not appear but reception will still be attempted the following hour. 

 

TIME ZONE SETTING: 

 
 
 

 

The time zone default of the Weather Station is 0. To set a different time zone: 
1. 

The current time zone value starts flashing after exiting the Manual time setting.  

2. 

Using the MIN/MAX/+ key or -/HISTORY key to set the time zone. The range runs 
from 0 to +9 and then runs from -9 back to 0 in consecutive 1hour intervals. 

3. 

Press the ALARM/SET key to enter the Date setting mode. 

 

DATE SETTING: 

 
 
 

                                                                                           Date     Month        Year   

The date default of the Weather Station is 1. 1. in the year 1999. Once the radio-
controlled time signals are received, the date is automatically updated. However, if the 
signals are not received, the date can also be set manually.  
1. 

The year starts flashing after exiting the Time zone setting. 

2. 

Set the year by pressing the MIN/MAX/+ key or -/HISTORY key. The range runs 
from 1999 to 2020.  

3. 

Press the ALARM/SET key again to confirm and to enter the month setting mode. 
The month starts flashing. 

4. 

Using the MIN/MAX/+ key or -/HISTORY key, set the month required.  

5. 

Press the ALARM/SET key again to confirm and to enter the date setting mode. The 
date starts flashing. 

6. 

Using the MIN/MAX/+ key or -/HISTORY key, set the date required. 

7. 

Press the ALARM/SET key once more to confirm all settings or use the CHANNEL 
key for immediate exit of the set mode. 

 

LCD2- INDOOR RELATIVE HUMIDITY AND INDOOR TEMPERATURE: 

 

 

 

 

    

 
 
 

 

The indoor temperature and humidity are automatically updated and displayed on the 
second section of the LCD. 

 

TOGGLING AND RESETTING THE INDOOR RECORDINGS: 

1. 

To toggle between the indoor current, maximum and minimum temperature and 
humidity data, press the MIN/MAX/+ key: 
Once to show the maximum temperature and humidity values  
Twice to show the minimum temperature and humidity values  
Three times to return to the current temperature and humidity levels 

2. 

To reset the minimum and maximum temperature and humidity, press the 
MIN/MAX/+ key continuously for about 3 seconds. This will reset all minimum and 
maximum data recorded to the current displayed values. 

 

LCD3- WEATHER FORECAST, WEATHER TENDENCY, RELATIVE AIR 
PRESSURE, WEATHER ICON SENSITIVITY AND °C/°F SETTING: 

 

THE WEATHER FORECASTING ICONS: 

There are 3 weather icons in the third section of LCD which can be displayed in any of the 
following combinations: 
 
 
 
 
 

     Sunny                 Cloudy with sunny intervals             Rainy 

Indoor relative 
humidity in %

 

Indoor 
temperature 
in °C or ºF

 

Summary of Contents for 35.1018

Page 1: ...HER STATION 35 1018 STATION METEOROLOGIQUE COMMANDEE PAR RADIO 35 1018 RADIOGRAFISCH BESTUURD WEERSTATION 35 1018 STAZIONE METEREOLOGICA RADIO CONTROLLATO 35 1018 Bedienungsanleitung Instructions manual Notice d emploi Gebruiksaanwijzing Istruzioni d uso ...

Page 2: ...mm LIABILITY DISCLAIMER The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place This product is not to be used for medical purposes or for public information This product is only designed to be used in the home as indication of the future weather and is not 100 accurate Weather forecasts given...

Page 3: ... Weather Station has been designed to be hung on a wall or free standing For Free standing Pull out the easel on the back of the unit and place onto a flat surface To wall mount Before wall mounting please check that the outdoor temperature values can be received from the desired locations To wall mount 1 Fix a screw not supplied into the desired wall leaving the head extended out the by about 5mm...

Page 4: ...o the current pressure If the bars are rising it means that the weather is getting better due to the increase of air pressure If the bars go down it means the air pressure has dropped and the weather is expected to get worse from the present time 0h Note For accurate barometric pressure trends the Weather Station should operate at the same altitude for example it should not be moved from the groun...

Page 5: ...s displayed based on comparing the difference of the air pressure recorded during a full hour time frame Note A single weather tendency indicator will point upward or downward when the difference in air pressure registered is more than 1hPa but less than 2 5hPa within 4 hours Two weather tendency indicators pointing upward or downward will be displayed when the air pressure difference has increase...

Page 6: ...key or HISTORY key to set the time zone The range runs from 0 to 9 and then runs from 9 back to 0 in consecutive 1hour intervals 3 Press the ALARM SET key to enter the Date setting mode DATE SETTING Date Month Year The date default of the Weather Station is 1 1 in the year 1999 Once the radio controlled time signals are received the date is automatically updated However if the signals are not rece...

Page 7: ...TORY key to view all levels of contrast 3 Select the desired LCD contrast Confirm with the ALARM SET key and enter into the Manual Time setting To exit the manual setting mode immediately press the CHANNEL key anytime The mode will return to normal time display TIME SETTING RADIO CONTROLLED TIME RECEPTION The time base for the radio controlled time is a Cesium Atomic Clock operated by the Physikal...

Page 8: ...onds after inserting the batteries in the Weather Station 6 Once the outdoor temperature has been received and displayed on the Weather Station the DCF 77 time code reception is automatically started This takes typically between 3 5 minutes in good conditions 7 If after 10 minutes the DCF time has not been received use the SET key to manually enter a time initially The clock will automatically att...

Page 9: ...ature reading in C ºF with minimum and maximum recording Indoor humidity reading displayed as RH with minimum and maximum recording Outdoor temperature reading for up to 3 transmitters in C ºF with minimum and maximum and time and date of recording Wall mountable or table standing The Outdoor Temperature Transmitter Remote transmission of outdoor temperature to Weather Station by 433 MHz Rain proo...