background image

 

       

 
 
 
 
 
 

 

For every sudden or significant change in the air pressure, the weather icons will update 
accordingly to represent the change in weather. If the icons do not change, then it means 
either the air pressure has not changed or the change has been too slow for the Weather 
station to register. However, if the icon displayed is a sun or raining cloud, there will be no 
change of icon if the weather gets any better (with sunny icon) or worse (with rainy icon) 
since the icons are already at their extremes. 

 

The icons displayed forecasts the weather in terms of getting better or worse and not 
necessarily sunny or rainy as each icon indicates. For example, if the current weather is 
cloudy and the rainy icon is displayed, it does not mean that the product is faulty because 
it is not raining. It simply means that the air pressure has dropped and the weather is 
expected to get worse but not necessarily rainy. 

 

Note:

 

 

After setting up, readings for weather forecasts should be disregarded for the next 12-24 
hours. This will allow sufficient time for the Weather Station to collect air pressure data at 
a constant altitude and therefore result in a more accurate forecast. 

 

Common to weather forecasting, absolute accuracy cannot be guaranteed. The weather 
forecasting feature is estimated to have an accuracy level of about 75% due to the varying 
areas the Weather Station has been designed for use in. In areas that experience sudden 
changes in weather (for example from sunny to rain), the Weather Station will be more 
accurate compared to use in areas where the weather is stagnant most of the time (for 
example mostly sunny). 

 

If the Weather Station is moved to another location significantly higher or lower than its 
initial standing point (for example from the ground floor to the upper floors of a house), 
discard the weather forecast for the next 12-24 hours. By doing this, the Weather Station 
will not mistake the new location as being a possible change in air-pressure when really it 
is due to the slight change of altitude.  

 

WEATHER TENDENCY INDICATOR 

The Weather tendency indicators are located on the right hand side of the Weather icons 
and they work independently from the Weather forecast icons. The Weather tendency 
indicator pointing upward or downward directions is displayed based on comparing the 
difference of the air pressure recorded during a full hour time frame. 

 

 
 

Note:

 

 

A single weather tendency indicator will point upward or downward when the 
difference in air pressure registered is more than 1hPa but less than 2.5hPa within 4 
hours. 

 

Two weather tendency indicators pointing upward or downward will be displayed 
when the air pressure difference has increased or decr eased by 2.5hPa or more 
within 4 hours   

 

STORM WARNING INDICATOR: 

Two flashing downward tendency indicators will be visualized if the air pressure has 
dropped by 4 hPa or more in the last 6 hours. The storm indicator will stop flashing when 
the air pressure rises back to a steady level again. 

 

RELATIVE AIR PRESSURE FIGURES OF THE LAST 0-12 HOURS

 

The relative Air pressure history can be displayed numerically to view the air pressure 
changes over the last 0-12 hours (also see notes on “

LCD4-

 

Air Pressure History 

(electronic barometer with barometric pressure and trend)” 

below

). 

 

Press the -/HISTORY key to display the recorded air pressure changes during the 
last 0-12 full hours. The numeric recorded air pressure will be display accordingly to 
the hour. 

 

 

Note

Every full hour, the displayed air pressure is shifted into the storage of last 12 hours. “0h” 
represents the air pressure of the current hour according to the time display, “-1h” 
represents the air pressure recorded last full hour before and so on. 

 

WEATHER PARAMETER SETTINGS: 

 

RELATIVE AIR PRESSURE SETTING (hPa)

 

The reference Relative Air Pressure (hPa) can be set between 970 to 1030hPa as follows: 
1. 

Press the -/HISTORY key for about 3 seconds to enter the weather parameter set 
mode. The default reference pressure value starts flashing. Each press or holding 
of the MIN/MAX/+ key will increase the digits by 1 hPa. 

2. 

Press the -/HISTORY key again to enter the Weather Icon Sensitivity setting mode 
or use the CHANNEL key for immediate exit of the set mode.  

 

Note

:  

The default reference pressure value of the barometer is 1013 hPa. 

For an exact 

measurement it is necessary to adjust the barometer first to your local altitude

. Ask 

for the present atmospheric pressure of your home area (Local weather service, www, 
optician, calibrated instruments in public buildings, airport). 

 

WEATHER FORECASTING ICON SENSITIVITY SETTING 

The difference in Air pressure which makes a change of weather likely and leads to the 
indication of the corresponding Weather Forecasting Icon can be set between the range 
of 2-4 hPa as follows: 

Summary of Contents for 35.1018

Page 1: ...HER STATION 35 1018 STATION METEOROLOGIQUE COMMANDEE PAR RADIO 35 1018 RADIOGRAFISCH BESTUURD WEERSTATION 35 1018 STAZIONE METEREOLOGICA RADIO CONTROLLATO 35 1018 Bedienungsanleitung Instructions manual Notice d emploi Gebruiksaanwijzing Istruzioni d uso ...

Page 2: ...mm LIABILITY DISCLAIMER The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place This product is not to be used for medical purposes or for public information This product is only designed to be used in the home as indication of the future weather and is not 100 accurate Weather forecasts given...

Page 3: ... Weather Station has been designed to be hung on a wall or free standing For Free standing Pull out the easel on the back of the unit and place onto a flat surface To wall mount Before wall mounting please check that the outdoor temperature values can be received from the desired locations To wall mount 1 Fix a screw not supplied into the desired wall leaving the head extended out the by about 5mm...

Page 4: ...o the current pressure If the bars are rising it means that the weather is getting better due to the increase of air pressure If the bars go down it means the air pressure has dropped and the weather is expected to get worse from the present time 0h Note For accurate barometric pressure trends the Weather Station should operate at the same altitude for example it should not be moved from the groun...

Page 5: ...s displayed based on comparing the difference of the air pressure recorded during a full hour time frame Note A single weather tendency indicator will point upward or downward when the difference in air pressure registered is more than 1hPa but less than 2 5hPa within 4 hours Two weather tendency indicators pointing upward or downward will be displayed when the air pressure difference has increase...

Page 6: ...key or HISTORY key to set the time zone The range runs from 0 to 9 and then runs from 9 back to 0 in consecutive 1hour intervals 3 Press the ALARM SET key to enter the Date setting mode DATE SETTING Date Month Year The date default of the Weather Station is 1 1 in the year 1999 Once the radio controlled time signals are received the date is automatically updated However if the signals are not rece...

Page 7: ...TORY key to view all levels of contrast 3 Select the desired LCD contrast Confirm with the ALARM SET key and enter into the Manual Time setting To exit the manual setting mode immediately press the CHANNEL key anytime The mode will return to normal time display TIME SETTING RADIO CONTROLLED TIME RECEPTION The time base for the radio controlled time is a Cesium Atomic Clock operated by the Physikal...

Page 8: ...onds after inserting the batteries in the Weather Station 6 Once the outdoor temperature has been received and displayed on the Weather Station the DCF 77 time code reception is automatically started This takes typically between 3 5 minutes in good conditions 7 If after 10 minutes the DCF time has not been received use the SET key to manually enter a time initially The clock will automatically att...

Page 9: ...ature reading in C ºF with minimum and maximum recording Indoor humidity reading displayed as RH with minimum and maximum recording Outdoor temperature reading for up to 3 transmitters in C ºF with minimum and maximum and time and date of recording Wall mountable or table standing The Outdoor Temperature Transmitter Remote transmission of outdoor temperature to Weather Station by 433 MHz Rain proo...