background image

 

1. 

The current sensitivity value (relative air pressure value) will start flashing after 
exiting the Relative Air Pressure setting.

 

2. 

Use the MIN/MAX/+ key to modify the value. Each pressing of the key down will 
increase the digit by one hPa.

 

3. 

When the desired hPa is selected, press the -/HISTORY key again to enter the ºC 
or ºF setting or use the CHANNEL key for immediate exit of the set mode.

 

 

Note

:  

The hPa setting feature can be used in area where there may be constant changes in air 
pressure which do not necessarily reflect the changes in the weather. In such areas for 
example, the hPa might be set to 3hPa meaning that there will be no change of weather 
icons if the air pressure does not drop or increase by at least 3hPa. For areas where the 
weather is stagnant, the hPa can be set lower. 

 

ºC/ºF SETTING

 
 
 

 

To select the temperatures display in degree Celsius or in degree Fahrenheit (default 
setting is ºC): 
1. 

“ºC” appears in the LCD1 and starts flashing after exiting the Weather Forecasting 
Icon Sensibility set mode. The display of the temperature can be in degree Celsius 
(ºC) or in degree Fahrenheit (ºF).  

2. 

Press the MIN/MAX/+ key to toggle the temperature display unit. 

3. 

Press the -/HISTORY key to confirm the ºC/ºF

 

setting or use the CHANNEL key for 

immediate exit of the set mode. 

 

LCD4- AIR PRESSURE HISTORY (ELECTRONIC BAROMETER WITH 
BAROMETRIC PRESSURE AND TREND)

 

 
 
 
 
 
 
 
 
The bar chart indicates the air pressure trend over the last 48 hours in 7 steps, 0h, -1h,  
-3h, -6h, -12h, -24h, and -48h. The “0h” represents the current full hour air pressure 
recording. The number column on the right side of the chart represent the “hPa” (0, ±2, 
±4, ±6, and ±8). The “0“ in the middle of this scale is equal to the current pressure and 
each change (±2, ±4, ±6, and ±8) represents how high or low in “hPa“ the past pressure 
was compared to the current pressure. 

 

If the bars are rising it means that the weather is getting better due to the increase of air 
pressure. If the bars go down, it means the air pressure has dropped and the weather is 
expected to get worse from the present time “0h“. 

 

Note:   

For accurate barometric pressure trends, the Weather Station should operate at the same 
altitude for example, it should not be moved from the ground to the second floor of the 
house. Should the unit be moved to a new location, discard readings for the next 12-24 
hours. 

  

LCD5- OUTDOOR TEMPERATURE: 

 

 

 
 
 
 
 
 
 
 
 

 

The last LCD section can show the outdoor temperature, the reception indicator, the 
minimum or maximum reading. A number beside the temperature will also be shown if 
more than one transmitter has been used. 

 

TOGGLING AND RESETTING THE OUTDOOR RECORDINGS: 

1. 

To toggle between the outdoor current, maximum and minimum temperature data 
and the times they were recorded press the MIN/MAX/+ key: 
Once to show the maximum outdoor temperature value with the recorded time and 
date (flashing).  
Twice to show the minimum outdoor temperature value with the recorded time and 
date (flashing).  
Three times to return to the current displayed values.  

2. 

To toggle between transmitters, press the CHANNEL key: 
Once to show transmitter 2 
Twice to show transmitter 3 
Three times to return to transmitter 1 

Note: The transmitter number will only be displayed if there is more than one  

transmitter being used

3. 

To reset the minimum and maximum outdoor temperature, and the time at which 
they were recorded, press the MIN/MAX/+ key continuously for about 3 seconds. 
This will reset all minimum and maximum data recorded to the displayed values for 
that particular transmitter and the indoor data.  

 

Air pressure over the last 48 hours 

Air pressure scale  
(Pressure scale is in hPa) 

Outdoor data 
reception 
indicator

 

Minimum or Maximum 
Display

 

Outdoor Temperature 
in °C or ºF

 

Number showing Transmitter unit (only 
displayed if there is more than one 
transmitter)

 

Degree Celsius 

Summary of Contents for 35.1018

Page 1: ...HER STATION 35 1018 STATION METEOROLOGIQUE COMMANDEE PAR RADIO 35 1018 RADIOGRAFISCH BESTUURD WEERSTATION 35 1018 STAZIONE METEREOLOGICA RADIO CONTROLLATO 35 1018 Bedienungsanleitung Instructions manual Notice d emploi Gebruiksaanwijzing Istruzioni d uso ...

Page 2: ...mm LIABILITY DISCLAIMER The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place This product is not to be used for medical purposes or for public information This product is only designed to be used in the home as indication of the future weather and is not 100 accurate Weather forecasts given...

Page 3: ... Weather Station has been designed to be hung on a wall or free standing For Free standing Pull out the easel on the back of the unit and place onto a flat surface To wall mount Before wall mounting please check that the outdoor temperature values can be received from the desired locations To wall mount 1 Fix a screw not supplied into the desired wall leaving the head extended out the by about 5mm...

Page 4: ...o the current pressure If the bars are rising it means that the weather is getting better due to the increase of air pressure If the bars go down it means the air pressure has dropped and the weather is expected to get worse from the present time 0h Note For accurate barometric pressure trends the Weather Station should operate at the same altitude for example it should not be moved from the groun...

Page 5: ...s displayed based on comparing the difference of the air pressure recorded during a full hour time frame Note A single weather tendency indicator will point upward or downward when the difference in air pressure registered is more than 1hPa but less than 2 5hPa within 4 hours Two weather tendency indicators pointing upward or downward will be displayed when the air pressure difference has increase...

Page 6: ...key or HISTORY key to set the time zone The range runs from 0 to 9 and then runs from 9 back to 0 in consecutive 1hour intervals 3 Press the ALARM SET key to enter the Date setting mode DATE SETTING Date Month Year The date default of the Weather Station is 1 1 in the year 1999 Once the radio controlled time signals are received the date is automatically updated However if the signals are not rece...

Page 7: ...TORY key to view all levels of contrast 3 Select the desired LCD contrast Confirm with the ALARM SET key and enter into the Manual Time setting To exit the manual setting mode immediately press the CHANNEL key anytime The mode will return to normal time display TIME SETTING RADIO CONTROLLED TIME RECEPTION The time base for the radio controlled time is a Cesium Atomic Clock operated by the Physikal...

Page 8: ...onds after inserting the batteries in the Weather Station 6 Once the outdoor temperature has been received and displayed on the Weather Station the DCF 77 time code reception is automatically started This takes typically between 3 5 minutes in good conditions 7 If after 10 minutes the DCF time has not been received use the SET key to manually enter a time initially The clock will automatically att...

Page 9: ...ature reading in C ºF with minimum and maximum recording Indoor humidity reading displayed as RH with minimum and maximum recording Outdoor temperature reading for up to 3 transmitters in C ºF with minimum and maximum and time and date of recording Wall mountable or table standing The Outdoor Temperature Transmitter Remote transmission of outdoor temperature to Weather Station by 433 MHz Rain proo...

Reviews: