6
1.
The current sensitivity value (relative air pressure value) will start flashing after
exiting the Relative Air Pressure setting.
2.
Use the MIN/MAX/+ key to modify the value. Each pressing of the key down will
increase the digit by one hPa.
3.
When the desired hPa is selected, press the -/HISTORY key again to enter the ºC
or ºF setting or use the CHANNEL key for immediate exit of the set mode.
Note
:
The hPa setting feature can be used in area where there may be constant changes in air
pressure which do not necessarily reflect the changes in the weather. In such areas for
example, the hPa might be set to 3hPa meaning that there will be no change of weather
icons if the air pressure does not drop or increase by at least 3hPa. For areas where the
weather is stagnant, the hPa can be set lower.
ºC/ºF SETTING
:
To select the temperatures display in degree Celsius or in degree Fahrenheit (default
setting is ºC):
1.
“ºC” appears in the LCD1 and starts flashing after exiting the Weather Forecasting
Icon Sensibility set mode. The display of the temperature can be in degree Celsius
(ºC) or in degree Fahrenheit (ºF).
2.
Press the MIN/MAX/+ key to toggle the temperature display unit.
3.
Press the -/HISTORY key to confirm the ºC/ºF
setting or use the CHANNEL key for
immediate exit of the set mode.
LCD4- AIR PRESSURE HISTORY (ELECTRONIC BAROMETER WITH
BAROMETRIC PRESSURE AND TREND)
The bar chart indicates the air pressure trend over the last 48 hours in 7 steps, 0h, -1h,
-3h, -6h, -12h, -24h, and -48h. The “0h” represents the current full hour air pressure
recording. The number column on the right side of the chart represent the “hPa” (0, ±2,
±4, ±6, and ±8). The “0“ in the middle of this scale is equal to the current pressure and
each change (±2, ±4, ±6, and ±8) represents how high or low in “hPa“ the past pressure
was compared to the current pressure.
If the bars are rising it means that the weather is getting better due to the increase of air
pressure. If the bars go down, it means the air pressure has dropped and the weather is
expected to get worse from the present time “0h“.
Note:
For accurate barometric pressure trends, the Weather Station should operate at the same
altitude for example, it should not be moved from the ground to the second floor of the
house. Should the unit be moved to a new location, discard readings for the next 12-24
hours.
LCD5- OUTDOOR TEMPERATURE:
The last LCD section can show the outdoor temperature, the reception indicator, the
minimum or maximum reading. A number beside the temperature will also be shown if
more than one transmitter has been used.
TOGGLING AND RESETTING THE OUTDOOR RECORDINGS:
1.
To toggle between the outdoor current, maximum and minimum temperature data
and the times they were recorded press the MIN/MAX/+ key:
Once to show the maximum outdoor temperature value with the recorded time and
date (flashing).
Twice to show the minimum outdoor temperature value with the recorded time and
date (flashing).
Three times to return to the current displayed values.
2.
To toggle between transmitters, press the CHANNEL key:
Once to show transmitter 2
Twice to show transmitter 3
Three times to return to transmitter 1
Note: The transmitter number will only be displayed if there is more than one
transmitter being used
.
3.
To reset the minimum and maximum outdoor temperature, and the time at which
they were recorded, press the MIN/MAX/+ key continuously for about 3 seconds.
This will reset all minimum and maximum data recorded to the displayed values for
that particular transmitter and the indoor data.
Air pressure over the last 48 hours
Air pressure scale
(Pressure scale is in hPa)
Outdoor data
reception
indicator
Minimum or Maximum
Display
Outdoor Temperature
in °C or ºF
Number showing Transmitter unit (only
displayed if there is more than one
transmitter)
Degree Celsius