G5 Flue
Installation
The freestanding unit and flue system should be installed prior to the AF-Series fireplace being
installed (for horizontal termination for FS730: see next page, section G6).
Place the freestanding unit in the correct
location, complying with
the clearances specified in the previous
section.
Remove 2 screws on each side of the fas-
cia just below the top panel and pull towards
you to remove the fascia.
Fix the FS730 unit to the floor using the
four securing holes in each corner of the unit.
Refer to Section B3 for flexi flue and
converter box clearances.
Refer to section C of this installation
manual for minimum and maximum flue
lengths, restrictor settings for your installa-
tion, and all other flue information.
Run the black Ø230mm flue liner lengths
from the top of the freestanding unit until it
penetrates the Ø265mm ceiling hole.
Use the supplied Ceiling plate for
tidying the internal termination point of the
Ø230mm flue liner.
Run the 2x flexible flues down through the
Ø230mm flue liner and attach it to the Flue
Spigot Plate as per section C of this manual
Open the flue liner rodent guard and close
around the flexi flue. Rivet, screw or cable
tie the open end to prevent it from opening.
Bend the two perpendicular tabs down and
screw into the flue liner using a short self
tapping screw.
Note
: Take care when installing
the rodent guard to not cause damage to the
flexi flue.
Install flue termination as per section C of this manual
Note: Ensure a power supply is within 1m of the rear of the appliance.
Ceiling Ring
225mm
Flue liner
2x Flexible
flue inner
Coaxial to Colinear
conversion box
Duravent 4x6”
Rigid Direct-vent
flue
Rigid flue
Flexible flue clamped
to Flue Spigot Plate
AF700
Fireplace
FS730 Freestanding
Unit
Flue Liner
Rodent Guard
Ø265 mm
Ceiling hole