B
A
C
D
E
F
G
SER
VICE
19
Place the band clamp over the exhaust flexi flue. Position the band so that it aligns with the
fibreglass tape underneath (approximately 15mm off the planar surface of the transition
box). Tighten the band clamp.
ONLY TIGHTEN ENOUGH TO JUST HOLD AND PREVENT THE FLEXI FLUE FROM COM-
ING OFF THE SPIGOT IF PULLED ON. OVER TIGHTENING THE CLAMP WILL CRUSH &
DAMAGE THE FLEXI FLUE.
Pilot drill 3 X 3.00 diameter holes through the previously drilled holes in the band clamp and
into and through both the flexi flue and the exhaust spigot.
Screw a stainless steel self-tapping screw (provided with the fibre glass tape) into each of
the 3 holes.
Ensure that the joint is sound and secure.
The steel ‘flashing plate’ provided with the 46DVA-CT collinear kit may be used (if desired)
to force distances to combustible materials and provide a platform to screw onto
appropriately placed wooden joists (supports).
The joint on the 75mm intake spigot is achieved in the same manner however the fibreglass
tape is not required to be fitted to the intake spigot.