B
Creating the Cavity
B1
Cavity Shape
The standoff rails installed on the outside must only be removed when being installed into a masonry
cavity.
Note: a top is not required when creating the cavity
Height
Width
Depth
AF700
False Cavity
installation (top stand-
offs must be adjusted
to the upright position)
600mm
695mm
390mm +
minimum
65mm flue
clearances
Masonry install with
Standoff Rails
Removed.
585mm
685mm
385mm
AF960
False Cavity
installation (top stand-
offs must be adjusted
to the upright position)
600mm
945mm
405mm +
minimum
65mm flue
clearances
Masonry install with
Standoff Rails
Removed.
585mm
935mm
400mm
*Note: If cavity dimensions significantly exceed those specified, a register plate is available for pur-
chase through your local escea retailer (New Zealand Only).
False Cavity Installation Requirements