background image

User Manual

 12

Technical Data

Table 2

FEATURES

ECG604E

Burners

4

Wok

No

Ignition

220–240V~

Trivet

Enamel

Hob Material

201 Grade Stainless Steel

Features

Continous Ignition Device

Flame Failure Safety

Yes

Gas Connection

G1/2 thread

Gas Types

NG (LP conversion  
kit supplied)

COOKTOP PHYSICAL DIMENSIONS (mm)

Width

600

Depth

510

Height

95

CUT OUT DIMENSIONS (mm)

Width

560

Depth

490

ENERGY RATING (NG) – MJ/h

Auxiliary burner

4.3

Semi Rapid burner × 2

6.3

Rapid burner

10.8

Total MJ/h

27.7

•  This product is subject to continuous improvement,  

specifications are subject to change without prior notice. 

•  This product was tested in accordance with the following standards:  

AS/NZS 60335.2.102: 2018 & AS/NZS 60335.1: 2020

Summary of Contents for ECG604E

Page 1: ...Version V1 0 1022 Everything you need for your Gas Cooktop is in this User Manual Model s ECG604E...

Page 2: ...e our Support Team are here to help You can use our online Support Centre at anytime by visiting http support residentiagroup com au Or you can contact us via phone by dialing 1300 11 HELP 4357 It is...

Page 3: ...age 8 Using Your Cooktop Page 9 Burners Page 10 Cleaning Care Page 11 Troubleshooting Page 12 Technical Data Page 13 Installation Instructions Page 16 Gas Connection Page 19 LPG Conversion Page 20 Ele...

Page 4: ...nded and may cause fire electric shock or personal injury Attachments The use of attachments is not recommended by the appliance manufacturer and distributor as they may be hazardous Improper use Dama...

Page 5: ...are centrally located on the trivets Handles should be turned away from the front of the bench to avoid accidents Do not modify this appliance Only models fitted with flame safeguard can be used in m...

Page 6: ...ifferently YOUR Cooktop Figure 1A ECG604E A B D E C E F KEY A Stainless Steel Hob B Burner Control Knobs C Enamel Trivets D Auxiliary Burner E Semi Rapid Burner F Rapid Burner COOKTOP COMPONENTS ACCES...

Page 7: ...CING Servicing MUST only be carried out by authorised personnel To maintain safe operation it is recommended that the product be inspected every five years by an authorised service person If the suppl...

Page 8: ...ght within 5 seconds turn knob to OFF position wait to allow gas to disperse and then try lighting again Burners MUST be operated between 1 and 9 settings only To light a burner the knob must be turne...

Page 9: ...ous boil will not cook food any faster and will waste energy Figure 4 POTS AND PANS All common pots and pans aluminium stainless steel cast iron ceramic etc may be used on your new gas cooktop Ensure...

Page 10: ...of cleaner directly onto the hob Rub clean using a damp cloth or paper towels Use a damp cloth to remove all remaining traces of the cleaner which could otherwise burn on when the hob is next used Wi...

Page 11: ...lean ignition spark plugs No spark is obtained when control knob is activated Electricity supply is disconnected or switched off Switch on electricity or check fuses Ignition spark plugs wet or dirty...

Page 12: ...conversion kit supplied COOKTOP PHYSICAL DIMENSIONS mm Width 600 Depth 510 Height 95 CUT OUT DIMENSIONS mm Width 560 Depth 490 ENERGY RATING NG MJ h Auxiliary burner 4 3 Semi Rapid burner 2 6 3 Rapid...

Page 13: ...appliances Check the dimensions of the appliance as well as the dimensions of the gap to be cut in the kitchen unit The panels located above the work surface directly next to the appliance must be mad...

Page 14: ...is 10mm The edges of the hob must be a minimum distance of mm from a side or rear wall 700 mm between the highest point of the hob surface including the burners and the underside of any horizontal su...

Page 15: ...nstallation Remove any excess seal visible after installation WARNING Failure to fix the cooktop to the bench could result in loosening of the gas connection through movement of the cooktop and a gas...

Page 16: ...ooktop in accordance with AS NZS 5601 1 in particular section 5 9 and clause 6 10 1 8 or AS NZS 5601 2 in particular section 2 11 Where a hose assembly is used and the cooktop is in the installed posi...

Page 17: ...is a parallel thread and is connected to consumer piping or hose assembly Regulators are supplied pre adjusted and configured by the component maker for use with Natural Gas The appliance installer i...

Page 18: ...w then the inlet pressure may be too low and adjustment of an upstream regulator may be needed or an upstream regulator or valve with insufficient flow capacity may be present in the gas supply line I...

Page 19: ...e when all burners of the appliance are operating at maximum when the smallest burner of the appliance is operating at minimum Under these conditions the outlet pressure should not vary from the nomin...

Page 20: ...de 1 Green Yellow Earth 2 Blue Neutral 3 Brown Live IMPORTANT The wire which is coloured Green Yellow must be connected to the terminal which is marked with the letter E or by the Earth symbol WARNING...

Page 21: ...appliance has been converted to LPG then the bypass screw will HAVE to be screwed in until a small stable flame results Please ensure the supply pressure has been checked PRIOR to any adjustment Figu...

Page 22: ...User Manual 22 Attach your receipt to this page...

Page 23: ...please record details of your purchase below and staple your receipt on the opposite page Your serial number can be found on the rating plate of your Cooktop STORE DETAILS STORE NAME ADDRESS TELEPHONE...

Page 24: ...as the same meaning referred to in the ACL and includes a situation when an Appliance cannot be repaired or it is uneconomic for Residentia Group at its discretion to repair an Appliance during the Wa...

Page 25: ...ces come with a guarantee by Residentia Group that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any oth...

Page 26: ...ner s handbook e defects caused by normal wear and tear accident negligence alteration misuse or incorrect installations f a product dismantled repaired or serviced by any serviceman other than an aut...

Page 27: ...esatto house 27 This page is intentionally blank But if you want to draw something make notes or even write a recipe it s all yours...

Page 28: ...A RESIDENTIA GROUP INITIATIVE everything you need...

Reviews: