8 MAINTENANCE
0463 730 001
- 27 -
© ESAB AB 2021
8
MAINTENANCE
8.1
Overview
Regular maintenance is important for safe, reliable operation.
Only personnel with appropriate electrical skills (authorized staff) may remove safety plates.
CAUTION!
All warranty undertakings from the supplier cease to apply if the customer attempts
any work to rectify any faults in the product during the warranty period.
8.2
Power source
To maintain the performance and increase the lifetime of the power source it is mandatory to
clean the product regularly. How often depends on:
• The welding process,
• The arc time, and
• The working environment.
• the surrounding environment, that is grinding etc.
Tools needed for the cleaning procedure:
• torx screwdriver, T25 and T30
• dry compressed air at a pressure of 4 bar
• protective equipment like earplugs, safety glasses, masks, gloves, and safety shoes
CAUTION!
Make sure that the cleaning procedure is done in a suitable prepared workspace.
Cleaning procedure
1.
Disconnect the mains supply.
2.
Wait for 4 minutes to discharge the capacitors.
3.
Remove the side panels on the power source.
4.
Remove the top panel on the power source.
5.
Remove the plastic cover between the heat sink and fan (b).