3 TECHNICAL DATA
0463 732 001
- 10 -
© ESAB AB 2020
Rogue ES 180i
Rogue ES 150i
Transportation temperature
-20 to +55 °C
(-4 to +131 °F)
-20 to +55 °C
(-4 to +131 °F)
Continual sound pressure at
no-load
<70 dB
<70 dB
Dimensions l × w × h
403×153×264 mm
(15.8 × 6 × 10.4 in.)
403×153×264 mm
(15.8 × 6 × 10.4 in.)
Weight
6.8 kg
6.8 kg
Insulation class transformer
H
H
Enclosure class
IP23S
IP23S
Application class
Mains supply, S
sc min
Minimum short circuit power on the network in accordance with IEC 61000-3-12.
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or
cut at a certain load without overloading. The duty cycle is valid for 40 °C / 104 °F, or below.
Enclosure class
The
IP
code indicates the enclosure class, i.e. the degree of protection against penetration
by solid objects or water.
Equipment marked
IP23S
is intended for indoor and outdoor use; however, should not be
operated in precipitation.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.