4.4
Mains power supply
Check that the unit is connected to the correct mains power supply voltage, and that
it is protected by the correct fuse size. A protective earth connection must be made,
in accordance with regulations.
Rating plate with supply connection data
Recommended fuse sizes and minimum cable area
Mig C170 3ph
Mig C200 3ph
Mig C250 3ph
Voltage V
400-415V,
3
∼
50/60 Hz
400-415V,
3
∼
50/60 Hz
230 / 400-415V,
3
∼
50/60 Hz
Current A
at 100% duty cycle
4.0
5.3
12.1/7.0
at 60% duty cycle
6.1
6.8
17.6/10.2
at 35% duty cycle
8.9
10.1
25.3/14.6
Mains Cable area
mm
2
4 x 1.5
4 x 1.5
4 x 2.5 / 4 x 1.5
Fuse
slow
A
10
10
25/16
NB:
The mains cable areas and fuse sizes shown above are in accordance with Swedish regulations.
They may not be applicable in other countries: make sure that the cable area and fuse sizes comply
with the relevant national regulations.
5
OPERATION
General safety regulations for handling the equipment can be found on
page
4
. Read through before you start using the equipment!
WARNING
Rotating parts can cause injury, take great care.
WARNING
To prevent the reel from sliding off the hub: Lock the
reel in place by turning the red knob as shown on the
warning label attached next to the hub.
GB
Summary of Contents for Origo Mig C170 3ph
Page 2: ... 2 ...
Page 14: ... ESAB AB 2012 Diagram 14 ba46e Mig C170 3ph 400 415V ...
Page 15: ... ESAB AB 2012 15 ba46e Mig C200 3ph 400 415V ...
Page 16: ... ESAB AB 2012 16 ba46e Mig C250 3ph 400 415V ...
Page 17: ... ESAB AB 2012 17 ba46e Mig C250 3ph 230 400 415V ...
Page 21: ... 21 ba46hints ...
Page 22: ... 22 ba46hints ...
Page 23: ... 23 ba46hints ...