© ESAB AB 2002
- 9 -
bm34d1ea
5.1
Connections and control devices
1
Display
9
Connection for welding gun
2
Knob for setting the voltage
10
Switch for 2-stroke / 4-stroke
3
Knob for setting crater filling time
11
Knob for setting burnback time
4
Switch for creep start OFF / ON
12
Connection for welding current from power
source, (OKC)
5
Knob for setting wire feed speed.
13
Connection for control cable from power
source
6
Connection for remote control unit,
Miggytrac, Railtrac
14
Connection RED for cooling water to
power source (cooling unit)
7
Connection BLUE, with ELP* for cooling
water to the welding gun
15
Connection BLUE for cooling water from
power source (cooling unit)
8
Connection RED for cooling water from
welding gun
16
Connection for shielding gas
NOTE! Display (digital instrument) and cooling water connections only available on certain models.
* ELP = ESAB Logic Pump, see point
5.2
.
5.2
Water connection
When connecting a water-cooled welding gun, the power source's main power
supply switch must be in the Off position and the cooling unit switch must be in
position “ELP/0”.
The wire feed unit with water connection is equipped with a detection system
ELP
(
E
SAB
L
ogic
P
ump) which checks that the water hoses are connected. When
connecting a water-cooled welding gun, the water pump starts.
Detection only works with power sources that are equipped with ELP.
5.3
Starting procedure
When the wire feed starts, the power source generates welding voltage.
If there is no welding current flow within three seconds, the power source switches
the welding voltage off. The wire feed continues until the welding gun's switch is
switched off.
GB
Summary of Contents for Origo M13 Feed 304
Page 2: ...2...
Page 15: ...15 p...
Page 17: ...ESAB AB 2002 17 bm34e11a...
Page 18: ...ESAB AB 2002 18 bm34e11a Feed 304 M13 valid for serial no 917 xxx xxxx...
Page 19: ...ESAB AB 2002 19 bm34e11a...
Page 20: ...20 p...
Page 23: ...Feed 304 ESAB AB 2002 23 bm34whj1...
Page 31: ...31 notes NOTES...