![ESAB Origo M 12 Feed 304 Instruction Manual Download Page 10](http://html1.mh-extra.com/html/esab/origo-m-12-feed-304/origo-m-12-feed-304_instruction-manual_2425097010.webp)
© ESAB AB 2003
- 10 -
bm33d1ea
5.4
Function explanations
Burnback time
Burnback time is a delay between the time when the wire starts to brake until the
time when the power source switches off the welding voltage. Too short burnback
time results in a long wire stickout after completion of welding, with a risk of the wire
being caught in the solidifying weld pool. Too long a burnback time results in a
shorter stickout, with increased risk of the arc striking back to the contact tip.
Creep start
Creep start means that the wire is fed at low speed until it comes into electrical
contact with the workpiece and then the speed increases to the set speed.
2 stroke
With
2 stroke,
the gas flow and wire feed start when the trigger switch is pressed in
and end when it is released.
4 stroke
With
4 stroke,
the gas flow starts when the trigger switch is pressed in and the wire
feed starts when it is released. The welding process continues until the switch is
pressed in again, the wire feed stops and when the switch is released the gas stops
flowing.
Wire feed speed
This sets the required feed speed of the filler wire in m/minute.
GB
Summary of Contents for Origo M 12 Feed 304
Page 2: ...2...
Page 15: ...ESAB AB 2003 15 bm33e11a...
Page 16: ...ESAB AB 2003 16 bm33e11a Feed 304 M12 valid from serial no 917 xxx xxxx...
Page 17: ...ESAB AB 2003 17 bm33e11a...
Page 18: ...18 p...
Page 21: ...Feed 304 ESAB AB 2003 21 bm33whj1...
Page 24: ...Feed 484 ESAB AB 2003 24 bm33whk1...
Page 30: ...30 notes NOTES...
Page 31: ...31 notes NOTES...